3. TROUBLESHOOTING AND ACTION TO BE TAKEN<br />

B–<strong>62075E</strong>/<strong>03</strong><br />

(4) Displaying the type of an alarm<br />

The type of the alarm issued is displayed.<br />

When the alarm status is released, the corresponding bit is set to 0.<br />

Number<br />

Bit<br />

1007 #<strong>15</strong> #14 #13 #12 #11 #10 #9 #8<br />

Number<br />

Bit<br />

1008 #7 #6 #5 #4 #3 #2 #1 #0<br />

Each bit indicates an alarm type when 1 is displayed for the bit as follows:<br />

#0 : Background P/S alarm<br />

#1 : Foreground P/S alarm<br />

#2 : Overheating<br />

#3 : Sub–CPU error<br />

#4 : Excessive synchronous error<br />

#5 : Parameter writing switch on<br />

#6 : Overtravel/external data input/output error<br />

#7 : PMC error<br />

#8 : External alarm message<br />

#9 : Not used.<br />

#10 : Serious P/S<br />

#11 : Not used.<br />

#12 : Servo alarm<br />

#13 : I/O error<br />

#14 : Input of a parameter requiring power disconnection<br />

#<strong>15</strong> : System error<br />

(5) Displaying the warning status<br />

The warning status is displayed.<br />

When the warning status is released, the bit is set to 0.<br />

Number<br />

Bit<br />

1009 #7 #6 #5 #4 #3 #2 #1 #0<br />

A bit indicates the following status when 1 is displayed for it.<br />

#0 : The system is in the warning state.<br />

#1 to #7 : Not used.<br />