OPERATINGHEATERManually-ControlledModelsContinued5. Press in control knob and turn counterclockwise C-clockwise to the PILOT position.Keep control knob pressed in for five (5) seconds (see Figure 23).Note: You may be running this <strong>heater</strong> for the first time after hooking up to <strong>gas</strong>supply. If so, the control knob may need to be pressed in for 30 seconds. This willallow air to bleed from the <strong>gas</strong> system.• If control knob does not pop out when released, contact a qualified serviceperson or <strong>gas</strong> supplier for repairs.6. With control knob pressed in, press and release ignitor button. This will light pilot.The pilot is attached to the front burner. If needed, keep pressing ignitor buttonuntil pilot lights.Note: If pilot does not light, contact a qualified service person or <strong>gas</strong> supplier forrepairs. Until repairs are made, light pilot with match. To light pilot with match,see Manual Lighting Procedure, below.7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,release control knob.Note: If pilot goes out, repeat steps 3 through 7.Ignitor ElectrodeThermocouplePilot BurnerFigure 24 - Pilot8. Turn control knob counterclockwiseC-clockwiseto the LOW position. The frontburner should light. Set control knob to either HIGH, MEDIUM, or LOW. To turncontrol knob from LOW to a higher setting, press in the control knob and turncounterclockwise C-clockwise . On LOW and MEDIUM positions, only front burneroperates. On HIGH position, front and rear burner operates.WARNING ICON G 001WARNINGHIGH, MEDIUM, and LOW are locked positions. You must press incontrol knob before turning it from these positions. Do not operate<strong>heater</strong> between locked positions or sooting could occur.WARNING ICON G 001CAUTIONDo not try to adjust heating levels by using the manual shutoff valve.TO TURN OFF GAS TO APPLIANCEShutting Off Heater1. Press in and turn control knob clockwise Clockwise to the PILOT position.2. Press in control knob and turn clockwise Clockwise to the OFF position.Shutting Off Burners Only (pilot stays lit)1. Press in and turn control knob clockwise Clockwise to the PILOT position.101309MANUAL LIGHTING PROCEDURE1. Follow steps 1 through 5 under Lighting Instructions, page 22.2. Depress control knob and light pilot with match.3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30seconds, release control knob. Now follow step 8, above.23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!