TROUBLE-SHOOTINGContinuedOBSERVEDPROBLEMOne or both burnersdo not light afterODS/pilot is litPOSSIBLECAUSE1. Inlet <strong>gas</strong> pressure istoo low2. Burner orifice(s)c<strong>log</strong>ged3. Mislocated crossovertube4. Burner orifice(s)diameter is too smallREMEDY1. Contact local <strong>propane</strong><strong>gas</strong> company2. Clean burner(s) (seeCleaning and Maintenance,page 25) orreplace burner orifice(s)3. Contact qualified serviceperson4. Replace burner orifice(s)Delayed ignition ofone or both burners1. Manifold pressure istoo low2. Burner orifice(s)c<strong>log</strong>ged3. Mislocated crossovertube1. Contact local <strong>propane</strong><strong>gas</strong> company2. Clean burner(s) (seeCleaning and Maintenance,page 25) orreplace burner orifice(s)3. Contact qualified servicepersonBurner backfiringduring combustion1. Burner orifice isc<strong>log</strong>ged or damaged2. Damaged burner3. Gas regulator defective1. Clean burner (seeCleaning and Maintenance,page 25) orreplace burner orifice2. Replace damaged burner3. Replace <strong>gas</strong> regulatorYellow flame in frontburner during burnercombustion1. Not enough air2. Gas regulator defective1. Check burner(s) for dirtand debris. If found,clean burner(s) (seeCleaning and Maintenance,page 25)2. Replace <strong>gas</strong> regulatorSlight smoke or odorduring initial operation1. Residues from manufacturingprocessesand <strong>log</strong>s curing1. Problem will stop after afew hours of operationHeater produces awhistling noise whenburners are lit1. Turning control knobto HI position whenburners are cold2. Air in <strong>gas</strong> line3. Air passageways on<strong>heater</strong> blocked4. Dirty or partiallyc<strong>log</strong>ged burnerorifice(s)1. Turn control knob to LOposition and let warm upfor a minute2. Operate burners until airis removed from line.Have <strong>gas</strong> line checkedby local <strong>propane</strong> <strong>gas</strong>company3. Observe minimuminstallation clearances(see pages 10-13)4. Clean burners (seeCleaning and Maintenance,page 25) orreplace burner orifice(s)Moisture/condensationnoticed on windows1. Not enough combustion/<strong>vent</strong>ilationair1. Refer to Air for Combustionand Ventilationrequirements (page 5)Continued27101309

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!