INSTALLINGContinuedINSTALLATION AND CLEARANCES (Vent-Free Operation Only)WARNINGMaintain the minimum clearances. If you can, provide greater clearancesfrom floor, ceiling, and adjoining wall.MINIMUM FIREPLACE CLEARANCETO COMBUSTIBLE MATERIALSLog Size Side Wall Ceiling Floor18", 24", 30" 16" 42" 5"LOG SIZING REQUIREMENTSLog Minimum Firebox SizeSize Height Depth Front Width Rear Width18" 17" 14" 20" 14"24" 17" 14" 26" 18"30" 17" 14" 32" 22"Carefully follow the instructions below. This will ensure safe installation into amasonry or U.L. listed manufactured fireplace.Minimum Wall and Ceiling Clearances (see Figure 4)A. Clearances from the side of the fireplace opening to any combustible wallshould not be less than 16 inches.B. Clearances from the top of the fireplace opening to the ceiling should not beless than 42 inches.42"16"Figure 4 - Minimum Clearance to Wall and Ceiling101309Continued9