Installation (cont'd):<br />

<strong>Injection</strong> <strong>Lubricator</strong> Options<br />

Pulse Generator:<br />

In those applications where the maximum amount<br />

of oil delivery is not enough, or flow is continuous,<br />

the <strong>L50</strong> is available with an optional Pulse Generator<br />

(“G” option). The pulse generator fires the injector<br />

module at the start of each cycle, and then at specified<br />

intervals (adjustable between 1 sec. and 20 sec.)<br />

within the cycle. The unit will not fire if the tool is not in<br />

use. The Pulse Generator assembly may be ordered<br />

separately as RK<strong>L50</strong>G.<br />

Pulse Generator<br />

<strong>Injection</strong> <strong>Lubricator</strong> Troubleshooting<br />

1.) Injector actuates when tool/equipment is activated,<br />

but no oil is dispensed.<br />

2.) Injector module does not actuate when tool/<br />

equipment is activated.<br />

3.) Air leaks constantly from grooves in sensor body<br />

under the injector module.<br />

4.) Air and/or oil leaks from top or bottom of injector<br />

module, cycle counter, or pulse generator.<br />

5.) Cycle counter does not make injector fire at the<br />

pre-determined 12, 24, 48, 96 or 192 cycle count.<br />

6.) Cycle counter allows injector to fire all the time (or<br />

more than it should).<br />

7.) Pulse generator not timing consistently.<br />

Cycle Counter:<br />

For those applications where the minimum oil delivery<br />

per cycle is too much, the <strong>L50</strong> is available with an<br />

optional cycle counter. Located below the injector<br />

module, it counts the number of equipment cycles.<br />

With a counter installed, the injectors will not fire until<br />

the counter has reached the desired number of cycles.<br />

Cycle Counter Adjustment:<br />

The cycle counter has four positions:<br />

Off: Oil injector module will not operate<br />

1: Oil Injector module operates with every cycle<br />

5: Oil injector module operates every fifth cycle<br />

10: Oil injector module operates every tenth cycle<br />

Push switch to desired<br />

setting for lube injection<br />

every 1, 5, or 10 tool cycles.<br />

1 10<br />

5<br />

COUNTS/CYCLE<br />

Cycle<br />

Counter<br />

Problem Probable Cause<br />

Check to make sure oil supply is adequate and that<br />

injector has been properly primed and purged of all air<br />

in oil supply (see priming instructions).<br />

The minimum airflow through the lubricator must be at<br />

least 5 SCFM or injector module will not fire.<br />

This is generally caused by foreign material being<br />

caught in the flow sensor piston bore in the sensor<br />

body preventing it from closing.<br />

O-ring seals are either cut or misaligned or two Phillips<br />

head screws holding the top-plate are loose.<br />

The two Phillips head screws holding the top-plate<br />

are over-torqued (should be 30-40 in. lbs.) or internal<br />

counter problem.<br />

The two Phillips head screws holding the top plate are<br />

under-torqued (should be 30-40 in. lbs.) or internal<br />

counter problem.<br />

The air logic timer has become contaminated with<br />

either liquid or particulate matter.<br />

IS-<strong>L50</strong> 5