Installation (cont'd):<br />
<strong>Injection</strong> <strong>Lubricator</strong> Options<br />
Pulse Generator:<br />
In those applications where the maximum amount<br />
of oil delivery is not enough, or flow is continuous,<br />
the <strong>L50</strong> is available with an optional Pulse Generator<br />
(“G” option). The pulse generator fires the injector<br />
module at the start of each cycle, and then at specified<br />
intervals (adjustable between 1 sec. and 20 sec.)<br />
within the cycle. The unit will not fire if the tool is not in<br />
use. The Pulse Generator assembly may be ordered<br />
separately as RK<strong>L50</strong>G.<br />
Pulse Generator<br />
<strong>Injection</strong> <strong>Lubricator</strong> Troubleshooting<br />
1.) Injector actuates when tool/equipment is activated,<br />
but no oil is dispensed.<br />
2.) Injector module does not actuate when tool/<br />
equipment is activated.<br />
3.) Air leaks constantly from grooves in sensor body<br />
under the injector module.<br />
4.) Air and/or oil leaks from top or bottom of injector<br />
module, cycle counter, or pulse generator.<br />
5.) Cycle counter does not make injector fire at the<br />
pre-determined 12, 24, 48, 96 or 192 cycle count.<br />
6.) Cycle counter allows injector to fire all the time (or<br />
more than it should).<br />
7.) Pulse generator not timing consistently.<br />
Cycle Counter:<br />
For those applications where the minimum oil delivery<br />
per cycle is too much, the <strong>L50</strong> is available with an<br />
optional cycle counter. Located below the injector<br />
module, it counts the number of equipment cycles.<br />
With a counter installed, the injectors will not fire until<br />
the counter has reached the desired number of cycles.<br />
Cycle Counter Adjustment:<br />
The cycle counter has four positions:<br />
Off: Oil injector module will not operate<br />
1: Oil Injector module operates with every cycle<br />
5: Oil injector module operates every fifth cycle<br />
10: Oil injector module operates every tenth cycle<br />
Push switch to desired<br />
setting for lube injection<br />
every 1, 5, or 10 tool cycles.<br />
1 10<br />
5<br />
COUNTS/CYCLE<br />
Cycle<br />
Counter<br />
Problem Probable Cause<br />
Check to make sure oil supply is adequate and that<br />
injector has been properly primed and purged of all air<br />
in oil supply (see priming instructions).<br />
The minimum airflow through the lubricator must be at<br />
least 5 SCFM or injector module will not fire.<br />
This is generally caused by foreign material being<br />
caught in the flow sensor piston bore in the sensor<br />
body preventing it from closing.<br />
O-ring seals are either cut or misaligned or two Phillips<br />
head screws holding the top-plate are loose.<br />
The two Phillips head screws holding the top-plate<br />
are over-torqued (should be 30-40 in. lbs.) or internal<br />
counter problem.<br />
The two Phillips head screws holding the top plate are<br />
under-torqued (should be 30-40 in. lbs.) or internal<br />
counter problem.<br />
The air logic timer has become contaminated with<br />
either liquid or particulate matter.<br />
IS-<strong>L50</strong> 5