3.4C. Installation and commission will be done through other tender.2.2 Unless otherwise described in the Technical Specifications, the scope of provision shallcover survey, designing & drawing, manufacturing, supplying, installing, testing,commissioning of equipment and material and its related facilities.2.3 The Bidder shall explain, in a separate and self-explanatory document with his offer, theprocess of expansion from the initial equipped capacities to the final capacities of theelements.2.4 Detail Technical Specifications of various components of the required system/service aregiven in subsequent chapters of this document. The bidder shall note that, until and unlessa specific work, equipment or service is defined as “Optional”, all the works, equipmentand services listed in various chapters of this document shall be deemed to be“Mandatory”. If the bidder disagrees, to provide any or many items of mandatory works,equipment or services, its bid shall automatically become “Non-Responsive” and shallnot be evaluated further.2.5 The Bidder shall note that, in addition to works related to the equipment, he has tocomplete, in each site, the following mandatory works. The bidder shall quote prices forsuch works and failure to quote for any of these works shall be treated as “noncompliance”and it shall be considered that the bidder proposes to complete these workscompletely “free of charge” to BTCL.2.5.1 Raised FloorSupply and Installation of ‘Raised Floor’ in all switch rooms. The average size of theswitch room shall be:a) 40 (forty) Sq. Meter for SS site.b) 20 (twenty) Sq. Meter for other Media Gateway sites.c) 15 (fifteen) Sq. meter for OMC room for all sites.d) 10 (ten ) Sq. Meter for each AGW site.Specification of The Raised Floor Tiles:a) Size: (60 cm * 60 cm) ± 20% , bottom part shall be enclosed with metallic casing.b) weight: > 30 kg per sq. meterThe actual area shall be fixed-up during BoQ preparation.2.5.2 False CeilingSupply and Installation of ‘False Ceiling’ in all switch rooms. The size of the switchroom shall be:a) 40 (forty) Sq. Meter for SS site.b) 20 (twenty) Sq. Meter for other Media Gateway sites.c) 15 ( fifteen) Sq. meter for OMC room for all sites.d) 10 ( ten ) Sq. Meter for each AGW site.The actual area shall be fixed-up during BoQ preparation.Book 2 :: Tender on Replacement of Old Telephones in Dhaka City Page: 11 of 153

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!