10.2.10 Trunk SupervisionThe system shall be equipped with appropriate software to continually superviseoperational condition of trunks. On detection of failures and faults, relevant trunks willbe automatically blocked. Minor and Major alarm conditions will be triggered whenpre-set threshold levels of blocked circuit numbers are crossed. These thresholds shallbe pre-set, for individual trunk circuit groups, by commands. Deviation shall be treatedas “Major Deviation”.10.2.11 Traffic Supervision and ControlThe system shall be equipped with appropriate software to continually supervise at leastthe following aspects of traffic conditions:a) Abnormal increase in originating and incoming callsb) Heavy traffic congestion on any trunk circuit groupc) Overload in call processing equipmentOverload control procedures shall be automatically activated and relevant alarmmessages shall be generated. Deviation shall be treated as “Major Deviation”.10.3 Fault Diagnosis ProtocolThe system shall be equipped with necessary software programs to test all the softwareand hardware packages of the system. The testing can be initiated:a) Automatically, on periodic intervals to test all the packages, andb) Automatically, upon detection of any fault or trouble, orc) Manually, by commandsThe results of the test shall indicate, as exactly as possible, the physical location of thesuspected package/ card. Deviation shall be treated as “Major Deviation” but theabsence of such facility shall be treated as “Critical Deviation”.10.4 System RestartThe system shall be provided with the following restart facilities:a) Automatic restart in case of faults which relate to interruption of call processingfunctionsb) Manual restart, by command, in case recovery is not possible with automaticrestartc) Manual restart, by operation of some hardware switches, when manual restart bycommand is not possibled) Manual restart, when it is necessary to upgrade system softwaree) Cold restart, in case of complete power shutdownDeviation shall be treated as “Major Deviation”.10.5 Trunk Circuit Testing10.5.1 The system shall be equipped with automatic and manual test facilities for checkingproper functioning and localizing faults on trunk circuits. The facilities shall be accessedby commands.Book 2 :: Tender on Replacement of Old Telephones in Dhaka City Page: 51 of 153

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!