<strong>Model</strong> 202-200-SPThe <strong>Model</strong> 202-200-SPvoltage monitor is designed to protect single-phase motors regardless of size.It can be used with 190V-240VAC, 50/60Hz motors to preventdamage caused by incoming power problems.A unique microcontroller-based voltage-sensing circuit constantly monitorsthe voltage to detect harmful power line conditions. When a harmfulcondition is detected, the MotorSaver's output relay is deactivated after aspecified trip delay.The output relay reactivates after power line conditionsreturn to an acceptable level for a specified amount of time (restart delay).The trip delay prevents nuisance tripping due to rapidly fluctuating powerline conditions.Available <strong>Model</strong>s:202-200-SP202-200-SP-NHVFeatures• Protects single-phase motors from:High and low voltageRapid cycling• Quick mounting with single screw• Small package, ideal for assembly into panels• Standard 1/4” quick connectsSpecificationsSingle-Phase Line Voltage202-200-SP, 202-200-SP-NHV • • • 190-240VACFrequency • • • • • • • • • • • • • • 50*/60HzLow Voltage (% of setpoint)Trip • • • • • • • • • • • • • • • • • • • 90%Reset • • • • • • • • • • • • • • • • • • 93%High Voltage (% of setpoint) (Not available on -NHV model)Trip • • • • • • • • • • • • • • • • • • • 110%Reset • • • • • • • • • • • • • • • • • • 107%Trip Delay TimeHigh and Low Voltage • • • • • • • • 4 secondsRestart Delay TimeAfter a fault orcomplete power loss • • • • • • • • Manual, 2-300 seconds adjustableOutput Contact RatingSPDT • • • • • • • • • • • • • • • • • • 480VA @ 240VAC Pilot Duty• • • • • • • • • • • • • • • • • • • • • • or 10A @ 240VAC Gen. PurposeTransient Protection • • • • • • IEC 1000-4-5, ±4kVPower Consumption • • • • • • 5 Watts (max.)Weight • • • • • • • • • • • • • • • • 8 oz.Trip & Reset Accuracy • • • • • ±1%Repeatability • • • • • • • • • • • • ±0.5%Input to Output Dielectric • • 1960 Vrms (min.)Termination • • • • • • • • • • • • • 0.25" Male Quick ConnectHumidity • • • • • • • • • • • • • • • 95% Relative Non CondensingOperating Temperature • • • • -40˚ to 70˚CCE PendingUL Recognized • • • • • • • • • • • File # E68520*Note: 50Hz will increase all delay timers by 20%.30 www.symcom.com • tel: 605-348-5580 800-843-8848 • fax: 605-348-5685

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!