<strong>Model</strong> ISS-105The ISS-105 IS Super Cellis a “smart” five-channel intrinsically safe relay and pump controller.The IS Super Cell can be configured for a wide variety ofapplications including alternating or non-alternating duplex, duplexseparate pump stop (SPS), triplex, and quadplex applications. It canbe set up for pump up or pump down applications or can be usedas a five-channel relay.Available <strong>Model</strong>s:ISS-105 (Intrinsically-Safe & Pump Controller)ISS-105-ISO (Intrinsically-Safe Only)ISS-105-ISO-F (Intrinsically-Safe Only with Fast Trip Relays)The IS Super Cell has a long list of features that are needed formultiple pump applications. The IS Super Cell can indicate low, highand out-of-sequence alarms. If an out-of-sequence alarm occurs, theskipped pump(s) will be started as intended. The <strong>Model</strong> ISS-105can be set up to do non-alternating control, alternating control andalternating control with one non-alternating pump.The non-alternating pump is intended for use with an emergency orjockey pump. The IS Super Cell can start an emergency pump onceevery 50 cycles to keep it working freely. Using the built-in DIPswitches, individual pumps can be disabled when taken out ofservice for repair or maintenance.Features• 5 intrinsically safe input channels meetingUL 913 Sixth Edition,August 8, 2002• 4 normally open output relays & 1 SPDT output relay• Field selectable pump control options• Duplex pump control• Duplex SPS (separate pump stop) pump control• Triplex pump control• Quadplex pump control• Out-of-sequence alarm• High and/or low alarm options depending on the numberof pumps and settings• Audible alarm output• Meets IEC EMC standards for Electrical Fast Transients (EFT),Electrostatic Discharge (ESD) and Radio Frequency Immunity (RFI)• DIN rail or surface mountable• User-selectable alternator/non-alternator option• Non-alternating pump option for emergency or jockey applications• Pump disable switches• Adjustable lag pump delay for all pumping modes• Adjustable delay-on-make/break timer in five-channel relay modeSpecificationsSupply Voltage • • • • • • • • • • • • 120VACEntity Parameters• • • • • • • •V oc = 16.8V Po=Voc*IscRelay Output Rating• • • • • • • • • • • • • • • • • • • • • I sc = 1.2mA 4General Purpose• • • • • • • • • • • • • 7A @ 240VACPilot Duty • • • • • • • • • • • • • • • • • 480VA @ 240VAC, B300• • • • • • • • • • • • • • • • • • • • • L a = 100mH• • • • • • • • • • • • • • • • • • • • • C a = 0.39uFRelay Contact Life (Electrical) • • • • 100,000 cycles min. @ rated load Standards PassedRelay Contact Life (Mechanical) • • • 10,000,000 cyclesOperating Temperature • • • • • • -40° to 55°CWeight • • • • • • • • • • • • • • • • • • 1.2 lbs.Power Consumption • • • • • • • • 5 Watts (max.)Wire range • • • • • • • • • • • • • • • 12 to 20 AWGElectrostatic Discharge (ESD) • • IEC 61000-4-2,Level 3,6kV contact,8kV air.Radio Frequency Immunity (RFI) • IEC 61000-4-2, Level 3, 10V/mFast Transients • • • • • • • • • • • • IEC 61000-4-4, Level 3, 4kV input power• • • • • • • • • • • • • • • • • • • • • • • 2kV Inputs/OutputsSafety Mark • • • • • • • • • • • • UL 913 Sixth Edition,August 8, 2002Recommended Terminal Torque • 3.5 to 4.5 in.-lbs. (max. 6 in.-lbs.)Provides intrinsically safe circuitsin the following locations:• • • • • Division I and II• • • • • • • • • • • • • • • • • • • • • • • • Class I, Groups A,B,C,D;• • • • • • • • • • • • • • • • • • • • • • • • Class II, Groups E,F,G;• • • • • • • • • • • • • • • • • • • • • • • • and Class III42 www.symcom.com • tel: 605-348-5580 800-843-8848 • fax: 605-348-5685
Pump ControllersPump Controllers are innovative products for controlling a single pump or multiple pumps. Some models can be used to detect pump sealleaks and motor overheating on submersible pumps. Other models can be used as a five-channel pump controller or five-channel switchto support all popular industry standard multi-pump configurations.Features• UL 508 listed (plug-in types must use and OT08-PC or RB08-PC octalbase socket manufactured by Custom Connector to qualify as UL listed)• DIN rail or surface mountable• Finger-safe terminals• LED status indicatorsProduct Selection Matrixwww.symcom.com • tel: 605-348-5580 800-843-8848 • fax: 605-348-568543