11.07.2015 Views

Model 777-KW/HP - SymCom

Model 777-KW/HP - SymCom

Model 777-KW/HP - SymCom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Model</strong> 460-15-100-SLDThe <strong>Model</strong> 460-15-100-SLDis a seal leak detector to sense seal failures on submersible pumps.A microcontrollerbasedrelay that monitors the shaft seal of a submersible pump motor. A resistiveprobe is installed in the seal cavity. If water leaks into the pump, the resistancemeasured by the probe decreases.When the resistance drops below the sensitivitysetpoint, the unit will trip and the relay contacts will change state. Output relay logiccan be reversed by removing an external jumper.The unit will automatically resetwhen a fault is cleared.See Appendix A, Figure 39 for typical wiring diagram.Part No. 460-15-100-SLDFeatures• DIN rail or surface mountable• Unique probe protection algorithm• Invertible relay logic• 4.7k to 100kΩ adjustable sensitivity• Microcontroller based• 2 relay contacts• LED status indicatorSpecificationsControl VoltageHi-Potential Test • • • • • • • • • • • • • • • Meets UL508460-15-100-SLD • • • • • • • • • • • • • • • 110/120VAC nominal• • • • • • • • • • • • • • • • • • • • • • • • (2 x rated V + 1000 V for 1 minute)Frequency • • • • • • • • • • • • • • • • • • 50*/60HzEnvironmentalSensitivity • • • • • • • • • • • • • • • • • • 4.7k-100kΩTemperature RangeOutput contact Rating – SPDTAmbient Operating • • • • • • • • • • • • • -40° to 70°C (-40° to 158°F)Pilot Duty • • • • • • • • • • • • • • • • • • • 360VA @ 240VACAmbient Storage • • • • • • • • • • • • • • • -40° to 80°C (-40° to 176°F)General Purpose • • • • • • • • • • • • • • • 8A @ 240VACClass of Protection • • • • • • • • • • • • IP20, NEMA 1 (finger safe)Power Consumption• • • • • • • • • • • 2 Watts (max.)Relative Humidity • • • • • • • • • • • • 10-95%, non-condensing per IEC 68-2-3Weight • • • • • • • • • • • • • • • • • • • • 1 lb. (max.)Enclosure• • • • • • • • • • • • • • • • • • • Polycarbonate*Note: 50Hz will increase all delay timers by 20%TerminalTorque • • • • • • • • • • • • • • • • • • • • • 6 in.-lbs.Wire• • • • • • • • • • • • • • • • • • • • • • • AWG 12-20 AWGSafety MarksUL • • • • • • • • • • • • • • • • • • • • • • • • UL 508 (File # E68520)Standards PassedElectrostatic Discharge (ESD) • • • • • • • IEC 100-4-2, Level 3, 6kV contact, 8kV airRadio Frequency Immunity, Radiated • • 159 MHz, 10 V/mFast Transient Burst IEC • • • • • • • • • • 1000-4-4, Level 3, 3.5kV input power and controlsSurgeIEC• • • • • • • • • • • • • • • • • • • • • • • • IEC 1000-4-5, Level 3, 4kV line-to-line;• • • • • • • • • • • • • • • • • • • • • • • • Level 4, 4kV line-to-groundANSI/IEEE • • • • • • • • • • • • • • • • • • • C62.41 Surge and Ring Wave Compliance• • • • • • • • • • • • • • • • • • • • • • • • to a level of 6kV line-to-linewww.symcom.com • tel: 605-348-5580 800-843-8848 • fax: 605-348-568547

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!