11.07.2015 Views

ACM - IHE

ACM - IHE

ACM - IHE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>IHE</strong> Patient Care Device Technical Framework Supplement – Alarm CommunicationManagement (<strong>ACM</strong>)______________________________________________________________________________ActorAlarm Reporter (AR)Alarm Manager (AM)Table X.2-1: <strong>ACM</strong> – Actors and OptionsOptionsReport Alarm Status optionIdentify Recipients optionWaveform Content Module (WCM) optionReport Alarm Status optionIdentify Recipients optionWaveform Content Module (WCM) in PCD-04 optionWaveform Content Module (WCM) in PCD-06 optionVol. &Section3.Y+13.Y+13.Y+13.Y+13.Y+13.Y+13.Y+1Alarm Communicator (AC) Waveform Content Module (WCM) 3.Y+1320325The Report Alarm Status option indicates whether or not the particular actor supports the ReportAlarm Status transaction (PCD-05).The Identify Recipients option for the Alarm Reporter identifies whether or not the Report Alarmtransaction (PCD-04) might include the identification of the notification recipient people ordevices.The Identify Recipients option for the Alarm Manager identifies whether or not the AlarmManager sends to the Alarm Reporter notification recipient details as to people or devicesnotified and replies.X.3 <strong>ACM</strong> Use Cases and Interaction Diagrams330335Alarm Communication Management is meant to improve clinical efficiency by using technologyto deliver the right alarms, with the right priority, to the right individuals via devices with theright content, and through configuration escalating communication of alarms to devicesassociated with other individuals.The following are the use cases. The use cases are noticeably generic and not so much focusedon the alarm clinical purpose as they are focused on the system interactions. The use cases maybe directly applicable to other <strong>IHE</strong> domains, and may be supplemented with additional use casesto serve specific needs in other domains.X.3.1 Case A1: Location Sourced340Use Case – Patient wants a pillow. Patient pulls nurse call. Nurse call system lights the room’sdome light and light at central station. Nurse call system, operating as an Alarm Reporter (AR)actor sends Report Alarm [PCD-04] to Alarm Manager (AM) indicating nurse call alarm. TheAlarm Manager (AM) logs receipt of the alarm. The Alarm Manager (AM) identifies theappropriate nurse based upon configured nurse to patient assignments, identifies the appropriateAlarm Communicator (AC) actor and destination communication device based upon nurse todevice configuration in Alarm Manager (AM), sends Disseminate Alarm [PCD-06] to nurse’s__________________________________________________________________________12Rev. 1.3– 2012-08-16Copyright © 2012: <strong>IHE</strong> International, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!