11.07.2015 Views

ACM - IHE

ACM - IHE

ACM - IHE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>IHE</strong> Patient Care Device Technical Framework Supplement – Alarm CommunicationManagement (<strong>ACM</strong>)______________________________________________________________________________3.Z.2 PID Patient Identification Segment845850This segment is required to be present and is populated with data used to identify the patientassociated with the alarm in the case where the identity is available from the Alarm Sourcesystem. If the patient identification is not available from the Alarm Source system, the alarmmay be location source based per <strong>ACM</strong> use case A1 in which case the PV1 segment identifiesthe location associated with the alarm. Additional information may be present to moreunambiguously identify the patient.Table 3.Z.2-1: HL7 Attribute Table – PID – Patient IdentificationSEQ LEN DT OPT RP/# TBL# ITEM# ELEMENT NAME3 250 CX O Y 00106 Patient Identifier List5 250 XPN O Y 00108 Patient name7 26 TSO O 00110 Date/Time of Birth8 1 IS O 00111 Administrative Sex3.Z.2.1 PID-3 Patient Identifier List (CX) 00106855This information may be used by the AM actor in the message sent to the AC actor to identifythe patient associated with the alarm within site specific HIPAA and electronic patient healthcareinformation policies.3.Z.2.2 PID-5 Patient Name (XPN) 00108860This information may be used by the AM actor in the message sent to the AC actor to identifythe patient associated with the alarm within site specific HIPAA and electronic patient healthcareinformation policies. Refer to PID-31 Identity Unknown Indicator for the means to identify thatwhile a PID segment is provided the identity of the patient is unknown.3.Z.2.3 PID-7 Date/Time of Birth (TSO) 00110This information may be used by the AM actor in the message sent to the AC actor to identifythe patient associated with the alarm within site specific HIPAA and electronic patient healthcareinformation policies.8653.Z.2.4 PID-8 Administrative Sex (IS) 00111This information may be used by the AM actor in the message sent to the AC actor to identifythe patient associated with the alarm within site specific HIPAA and electronic patient healthcareinformation policies.__________________________________________________________________________38Rev. 1.3– 2012-08-16Copyright © 2012: <strong>IHE</strong> International, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!