11.07.2015 Views

ACM - IHE

ACM - IHE

ACM - IHE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>IHE</strong> Patient Care Device Technical Framework Supplement – Alarm CommunicationManagement (<strong>ACM</strong>)______________________________________________________________________________SEQ LEN DT OPT RP/# TBL# ITEM# ELEMENT NAME18 22 EI O Y 01479 Equipment Instance Identifier3.Z.7.2 OBX-2 Value Type (ID) 005701495This field contains the format of the observation value in the OBX. For an alarm indication thisis CWE. This is to permit OBX-5.9 Original Text to optionally contain the human readilyrecognizable description of the alarm indication so as to avoid displaying MDC or otherencodings to notification dissemination recipients, often clinicians, assistants, or clinicalengineers.3.Z.7.3 OBX-3 Observation Identifier (CE) 0057115001505This field contains a unique identifier for the kind of measurement or device-dependent data thatis given in OBX-5 Observation Value of the current segment. It shall preferably be drawn fromthe MDC nomenclature, or, failing that, LOINC. Terms not in the MDC nomenclature should besubmitted to ISO/IEEE 11073 committee for possible standardization. Pending standardization,on a temporary basis by site agreement, agreed-on numeric codes and identifier strings in therange reserved in the standard for private codes may be used if necessary.3.Z.7.4 OBX-4 Observation Sub-ID (ST) 0057215101515This field is used to distinguish between multiple OBX segments with the same observation IDorganized under one OBR. The sub-identifier is also used to group related components. Thescheme used for alarms is an extension of that used in the DEC profile transactions formeasurements, which should be studied by those planning to use the Alarm CommunicationManagement supplement. It uses a dotted notation, where the elements are numbersdistinguishing the hierarchical containment levels of different measurements and differenttechnical subsystems within the ISO/IEE 11073 Domain Information Model of the patient caredevice, that is, ....In the Alarm Communications Management profile, a fifth element, , is added todistinguish the additional facets of an alarm, such as Alarm State, Phase, Inactivation State, andEvidentiary Data, that must be conveyed in associated additional OBX segments beyond thefirst.1520valueTable 3.Z.7.4-1: Observation Sub-ID FacetsFacet nameComments1 Event identification This facet specifies the MDC event code for the alarm2 Source identification Identifies the physiological measurement or technical sourceresponsible for the alarm.3 Event phase Whether the stimulus for the message is the beginning, end, or someother state or state transition of the alarm.__________________________________________________________________________56Rev. 1.3– 2012-08-16Copyright © 2012: <strong>IHE</strong> International, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!