<strong>Series</strong> <strong>IZS31</strong>Technical Data 2Electricity Removal CharacteristicsNote) Static electricity elimination features are based on the data using the charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S. ANSI standards(ANSI/ESD, STM3, 1-2000). Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject.2) Electricity removal rangeAir purge: NoAir purge: Yes (0.05 MPa to 0.7 MPa)Electricity removal rangeElectricity removal rangeFront/Rear distance to the ionizer - Charged object location (mm)Height 100 mmHeight 300 mmHeight 500 mm100 mm100 mmFront/Rear distance to the ionizer - Charged object location (mm)Height 500 mmHeight 1000 mmHeight 1500 mmHeight 2000 mm100 mm100 mmHorizontal distance to the ionizer - Charged object location (mm)Horizontal distance to the ionizer - Charged object location (mm)3) Installation height of feedback sensor and discharge time / Ion balanceAir purge: Yes (0.1 MPa)87Discharge time from 1000 V to 100 V9060Discharge time (sec)6543Without sensorIon balance (V)300–30Catalog specification value: ±30 V21With feedback sensor–6000 100 200 300 400 500Installation height of feedback sensor (mm)–900 100 200 300 400 500Installation height of feedback sensor (mm)IonizerFeedback sensor600 mm1056Charged plateInstallation height of feedback sensor