11.07.2015 Views

Series IZS31

Series IZS31

Series IZS31

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Series</strong> <strong>IZS31</strong>Specific Product Precautions 2Be sure to read before handling.CautionMounting1. Install the ionizer away from a wall as illustratedbelow.If a wall is located closer than the illustration below, the ionsgenerated will not be able to reach the object which requiresstatic electricity removal and therefore result in a decrease inefficiency.200 200 150 150Unit: mmAfter installation, be sure to verify the effects ofstatic electricity removal.The effects vary depending on the ambient conditions,operating conditions, etc. After installation, verify the effects ofstatic electricity removal.2. Install a feedback sensor away from the wall asillustrated below.The ionizer may fail to measure electrostatic potentialscorrectly if a wall or other obstacle exists within the clearancesshown in the following figure.WarningWiring / Piping1. Before wiring confirm if the power supply voltageis enough and that it is within the specificationsbefore wiring.Be sure to use UL Listed/Recognized 24 VDC power supplywith Class 2 output of under 2.1 A.2. Be sure to provide class-D grounding in order tomaintain product performance.If such grounding is not provided, not only may the ion balancebe disrupted but electric shocks may also result and theionizer or power supply may break down.BrownBlueDC power supply+24 VDCGNDClass-D groundB BACharged object(mm)A B10 2020 4025 4530 5540 6550 75BACharged object3. Be sure to turn off the power supply beforewiring (including attachment/detachment of theconnector).4. To connect a feedback sensor or autobalancesensor to the ionizer, use the cable included withthe sensor. Do not disassemble or modify theionizer.5. When applying the power supply, pay specialattention to the wiring and/or surroundingenvironment until the safety is confirmed.6. Do not connect or remove any connectorsincluding the power supply, while power is beingsupplied. Otherwise, the ionizer may malfunction.7. If the power line and high pressure line arerouted together, this product may malfunctiondue to noise. Therefore, use a separate wiringroute for this product.8. Be sure to confirm there are no wiring errorsbefore starting this product.Incorrect wiring will lead to damage or malfucntion to theproduct.9. Flush the piping before using.Before using this product, exercise caution to preventparticles, water drop, or oil from entering the piping.1080

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!