To keep the power consumption <strong>at</strong> an absolute minimum, two standard d<strong>at</strong>a loggers<br />
were selected to scan the sensors. The sampling r<strong>at</strong>e is 1Hz, and before being stored in a<br />
flash RAM unit the d<strong>at</strong>a are condensed to 10-min mean values together with maximum,<br />
minimum, and standard devi<strong>at</strong>ions for the averaging period. For the wind speed sensors<br />
a 5-s gust is calcul<strong>at</strong>ed as a mean of five consecutive 1 Hz values. The storage capacity<br />
of the flash RAM unit is equivalent to 9 months of d<strong>at</strong>a.<br />
The main components of the power supply were designed as simply as possible,<br />
comprising a m<strong>at</strong>rix of 2 x 5 x 50 W photovoltaic cells charging 25 NI-Cd b<strong>at</strong>teries with<br />
a capacity of 1070 Ah. The power system is capable of delivering 16 W continuously.<br />
However, due to a miscalcul<strong>at</strong>ion on the part of the erection contractor, the mast is<br />
oriented + 33.1 ° wrong. Because of this mistake the photovoltaic cells devi<strong>at</strong>e 33.1 °<br />
from facing directly south, and are therefore unable to achieve the envisaged power<br />
production. To compens<strong>at</strong>e for th<strong>at</strong> another 4 x 50 W photovoltaic cells were put up to<br />
deliver the needed power capacity.<br />
Figure 1.3 Fetch distances <strong>at</strong> <strong>Horns</strong> <strong>Rev</strong><br />
Direction Fetch (km)<br />
N 280<br />
NNE 62<br />
NE 36<br />
ENE 21<br />
E 25<br />
ESE 44<br />
SE 62<br />
SSE 80<br />
S 190<br />
SSW 240<br />
SW 700<br />
WSW 500<br />
W 600<br />
WNW 600<br />
NW 700<br />
NNW 700<br />
Every spring and autumn the primary met system is subjected to regular maintenance,<br />
and all sensors are replaced with newly calibr<strong>at</strong>ed sensors. Because the project has an<br />
extra set of sensors to replace the existing ones, the system is up and running again in<br />
only a few hours, and only one trip to the offshore mast is needed.<br />