Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
The microprocessor controller <strong>TC507</strong> allows an exactand reproduceable control of your kiln. The course ofa firing is shown in a figure which is seperated in upto 100 segments. One segment always consists of aramp (i.e. heat up or cooling) to a certain temperaturefollowed by a dwell at this temperature. Example:Temp(°C)8205405004600.00h250°C/h2:00h0:20h350°C/h0:55h0:10h0 1 2 3 4SKIP1:00h40°C/h2:00hSegmentNr.segment operation0 programme delay for delayed start (not used = 0 min)1 heating up at 250°C/h to 500°C with 20 min dwell2 heating up at 350°C/h to 820°C with 10 min dwell3 cooling at maximum speed (SKIP) to 540°C with 1 hour dwell4 cooling at 40°C/h to 460°C, no dwelltmptimermpdwellFor each segment the following values have to beentered:timeresp.rmpTemperature increase (or decrease). Can be enteredeither in degrees centigrade per hour (e.g. 250°C/h) oras time (e.g. 2:00 h). For uncontrolled hearing resp.cooling the value „skip“ is entered.tmpFinal Temperature of the ramp (e.g. 500°C). The rampends at this temperature.timeDwell time at this temperature (e.g. 20 min). Thetemperature is held for the time entered.4