<strong>Series</strong> <strong>2000</strong> <strong>Communications</strong> <strong>Handbook</strong>Digital <strong>Communications</strong> HardwareStrictly speaking, RS422 is a standard permitting ‘point to point’ connection of two pieces ofequipment using a full duplex, differential signal on two pairs of wires. In principle,therefore, an RS422 link only allows a single instrument to be connected to a PC. However,<strong>Series</strong> <strong>2000</strong> instruments provide an enhanced version of RS422 that also meets the fullelectrical requirements of RS485 described above. This allows up to 31 instruments to beconnected on the same network, but only with a 5 wire electrical connection. Thetransmission and reception of data use two pairs of twisted cable, with a separate cableprovided for common. The optional screen will provide additional noise immunity.The 2 wire RS485 should be used where possible for new installations where multi-dropcapability is required. RS422 is provided for compatibility with existing instruments.Some earlier instruments use a terminal marking that is different from that used in theRS422/RS485 standards. The table below compares this marking.RS422/RS485A'B'ABC & C'InstrumentRX+RX-TX+TX-CommonUsing RS232 or RS422/485, the <strong>Series</strong> <strong>2000</strong> instruments operate in a half duplex mode thatdoes not allow the simultaneous transmission and reception of data. Data is passed by analternating exchange.Most PC's provide an RS232 port for digital communications. The KD485 Comms Interfaceunit is recommended for interfacing to RS422/485. This unit is also used to buffer anRS422/485 network when it is required to communicate with more than 32 instruments onthe same bus, and may also be used to bridge 2 wire RS485 to 4 wire RS422 networksegments.. Wiring information for this unit is given at the end of this chapter., or refer toKD485 Installation and Operation Manual, available on request from your supplier, for a fulldescription.2.2. SELECTING RS232 OR RS422/485Changing between RS232, RS422, and RS485 is possible for 2400 <strong>Series</strong> instruments byreplacing the plug-in ‘H’ Module with a communications module of the required type.2200 <strong>Series</strong> communications hardware is a fixed build and must be specified when theinstrument is being ordered.<strong>Series</strong> <strong>2000</strong> <strong>Communications</strong> <strong>Handbook</strong> Part No HA026230 Issue 2.0 Feb-00 2-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!