12.07.2015 Views

ADL300 Elevator Drives for Synchronous ... - Sprecher + Schuh

ADL300 Elevator Drives for Synchronous ... - Sprecher + Schuh

ADL300 Elevator Drives for Synchronous ... - Sprecher + Schuh

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Note!The power terminal strip is extractable on sizes 2055 ... 3110. The EM terminal strip is extractable on all mechanical sizes.Size<strong>ADL300</strong>-...-2T,3ph2055 ... 3110Cable cross-sectionTerminals:on structural workLock screw diameterRecommendedterminalTightening torque (min)(mm 2 ) AWG (mm) (mm) (Nm)Same as the maximum cross-section used <strong>for</strong> thepower terminal stripM5 Eyelet - Fork 64150 16 6 M6 Eyelet - Fork 104185 16 6 M6 Eyelet - Fork 104220 16 6 M6 Eyelet - Fork 105300 50 1/0 M6 Eyelet - Fork 105370 50 1/0 M6 Eyelet - Fork 10Size<strong>ADL300</strong>-...-2M-... , 1phMaximum cable cross-section(flexible conductor)Morsetti: L1 - N - BR - C1 - C - D - U - V - W - EMRecommendedstrippingRecommendedterminalTighteningtorque (min)(mm 2 ) AWG (mm) (mm) (Nm)1011 4 10 10 None / pin 0.5 ... 0.61015 4 10 10 None / pin 0.5 ... 0.62022 6 8 10 None / pin 1.2 ... 1.52030 6 8 10 None / pin 1.2 ... 1.53040 16 6 14 None / pin 1.5 ... 1.73055 16 6 14 None / pin 1.5 ... 1.7Size<strong>ADL300</strong>-...-2M-... , 1ph1011 ... 3055Cable cross-sectionTerminals:on structural workLock screw diameterRecommendedterminalTightening torque (min)(mm 2 ) AWG (mm) (mm) (Nm)Same as the maximum cross-section used <strong>for</strong> thepower terminal stripM5 Eyelet - Fork 6Note!The minimum cross-section <strong>for</strong> both ground connections must comply with EN61800-5-1 prescriptions. Always ground both points on structural steel.7.1.2 Connection of shielding (recommended)BOptional Power Shield kit:- Cod. S726101 (sizes 1 and 2)- Cod. S726501 (size 3)ACLoosen the two screws (B), put the metal support (A) (optional, POWER SHIELD KIT) in place and screw down tightly.Fasten the power cable shield to the omega sections (C) as illustrated in the figure.• Sizes 4 and 5 : <strong>for</strong> these sizes the metal support (A) is not provided. Cable shielding must be provided by the installer.36 <strong>ADL300</strong> • Quick installation guide - Specifications and connection

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!