7.1.8 Motor connectionL1 L2 L3 BR C1 C D U V W EML1 L2 L3 BR1 BR2 C D U V W EMK3MK3MK2MK2MADL.-1040...3220-4ADL.-2055...3110-2TM3 phADL.-4300...5550-4ADL.-4150...5300-2TM3 phL1 L2 L3 C D U V W EML1 L2 BR C1 C D U V W EMK3MK3MK2MK2MADL.-5750-4ADL.-5370-2TM3 phADL.-1011...3055-2MM3 ph7.1.9 Connection of braking resistor (optional)L1 L2 L3 BR C1 C D U V W EML1 L2 L3 BR1 BR2 C D U V W EMBraking resistorADL.-1040...3220-4ADL.-2055...3110-2TBraking resistorADL.-4300...5550-4ADL.-4150...5300-2TL1 L2 BR C1 C D U V W EMBraking resistorADL.-1011...3055-2MNote! Recommended combination braking resistors: see paragraph 5.4.For sizes 5750 and 5370 an optional external BUy braking unit can be used and connected to terminals Cand D. Refer to the BUy handbook <strong>for</strong> further in<strong>for</strong>mation.40 <strong>ADL300</strong> • Quick installation guide - Specifications and connection