ROOFS A GUIDE TO THE REPAIR OF HISTORIC ROOFSPROPERTY ADDRESS: Furze House PROJECT REF: 312 FHCo. Laois DATE OF SURVEY: November 2007CLIENT’S NAME: SURVEYOR: LELocation <strong>of</strong> building / ro<strong>of</strong> in relation <strong>to</strong> main building: Main Ro<strong>of</strong>Approximate date <strong>of</strong> building:1720-1730s with late-18C addition <strong>to</strong> south-eastType <strong>of</strong> ro<strong>of</strong> (e.g. gabled, hipped, etc.):Double ‘ A’ with central valley and hipped endsArea on flat, m²: outer 306 m 2 , valleys 151 m 2Pitch in degrees: 42 degreesArea on plane <strong>of</strong> slope, m²: outer 412 m 2 , valleys 203 m 2 Rafter size and spacing: 115 x 80 mm @300 mm centresROOF FEATURESRo<strong>of</strong>lights: One access hatch; 2 no. dormersChimneys: 3 no. rendered with concrete caps and<strong>to</strong> valleys; 10 no. small glass panes light attic spaceornamental pots. Note: valley gutter drains thro’Ro<strong>of</strong> vents: Nonetwo front stacksAbutment / gable: NoneRidge: Dark grey, plain clay ridge tilesValleys: Polymer membrane over timber boarding;Hips: Lead rolls over timber formersdamaged and with inadequate fallsROOF SLOPE & PERIMETER Front, rear & hipped ends: Inner valleys:Original / non-original: Mid-late 20C Possibly originalCondition: OK, but limited life span Bitumen coveredType <strong>of</strong> slate: Cement, prob. asbes<strong>to</strong>s fibre Natural slateCoursing: 255 mm high x 310 mm wide Varies with random widthSize <strong>of</strong> slate: 12 x 24” (610 x 305 mm) 12 x 24”Gauge: 250 mm VariesNumber <strong>of</strong> slates (approx.): 5,500 2,700Colour <strong>of</strong> slate: Dark grey Grey/blue with green veinTexture <strong>of</strong> slate: Matt Smooth & finely grainedType <strong>of</strong> fixing: Galv. nails Wrought iron nailsParging / membrane: Bituminous membrane Lime parging; very looseEaves / parapet detail: Corbelled s<strong>to</strong>ne eaves / concrete n/aRainwater goods: Extruded aluminium n/aDIAGRAMAdditional notes:2 no. lead-lined timber box with 1 no. piped secret gutter through ro<strong>of</strong>Sample survey sheet for <strong>the</strong> assessment <strong>of</strong> ro<strong>of</strong> condition and record <strong>of</strong> detail47
ROOFS A GUIDE TO THE REPAIR OF HISTORIC ROOFSSURVEY OF ROOF STRUCTUREA survey <strong>of</strong> <strong>the</strong> ro<strong>of</strong> should be completed beforecarrying out repair or replacement works. This shouldstart with an assessment <strong>of</strong> <strong>the</strong> ro<strong>of</strong> structure:> What is it made <strong>of</strong>?> Is it structurally stable?> Is it in good condition?> Are <strong>the</strong>re dis<strong>to</strong>rtions and deflections?The ro<strong>of</strong> pr<strong>of</strong>ile and <strong>the</strong> materials used in itsconstruction and covering (including elements such aschimneystacks, ro<strong>of</strong> dormers and lanterns) should berecorded.The cause <strong>of</strong> any deterioration in condition will need<strong>to</strong> be determined. Particular attention should be paid<strong>to</strong> vulnerable areas where water is likely <strong>to</strong> penetratein<strong>to</strong> <strong>the</strong> interior <strong>of</strong> <strong>the</strong> building, for example at <strong>the</strong>ends <strong>of</strong> <strong>the</strong> rafters or at <strong>the</strong> flashings between <strong>the</strong>gable and <strong>the</strong> ro<strong>of</strong> slopes and at <strong>the</strong> base <strong>of</strong>chimneystacks. It should also be established whe<strong>the</strong>ror not <strong>the</strong>re is adequate ventilation <strong>of</strong> <strong>the</strong> ro<strong>of</strong> timbersand whe<strong>the</strong>r fixings are corroded. Checks should bemade for signs <strong>of</strong> fungal or insect attack in areaswhere ventilation is restricted, such as at rafter ends,behind parapets and around chimneystacks, andwhere pieces <strong>of</strong> lime parging may have fallen,blocking air flow between <strong>the</strong> rafters. The opportunityshould be taken <strong>to</strong> inspect <strong>the</strong> condition <strong>of</strong> such itemsas water tanks, access hatches and lights, chimneystacks and aerials, as well as rainwater goods andoutlets. Metal ro<strong>of</strong>lights should be examined for signs<strong>of</strong> corrosion or dis<strong>to</strong>rtion and for damaged coverflashings. Similarly, <strong>the</strong> structural stability <strong>of</strong>chimneystacks should be assessed; <strong>the</strong> capping orflaunching examined for cracks and lifted flashingsreplaced as soon as possible.If <strong>the</strong> ro<strong>of</strong> covering is <strong>to</strong> be fully or partially stripped,this provides an opportunity <strong>to</strong> inspect timbers inusually inaccessible areas around chimneystacks,below parapets and valleys, and along <strong>the</strong> head <strong>of</strong> <strong>the</strong>wall plate where it tends <strong>to</strong> be warmer and moresusceptible <strong>to</strong> rot outbreaks.STRUCTURAL APPRAISALIn order <strong>to</strong> make an informed decision on what repairsare necessary, a detailed survey <strong>of</strong> individual timbers,<strong>the</strong>ir layout, spacing, sizes and condition should becarried out. Once this survey information is ga<strong>the</strong>red, itwill be possible <strong>to</strong> identify and locate rotten timbersections which need <strong>to</strong> be supplemented, treated orremoved, and <strong>to</strong> locate where new timbers need <strong>to</strong> bescarfed or jointed in<strong>to</strong> <strong>the</strong> existing structure. The aim<strong>of</strong> any repair work should always be <strong>to</strong> retain as muchas possible <strong>of</strong> <strong>the</strong> existing his<strong>to</strong>ric timber and <strong>to</strong>supplement its structural capabilities where necessary.These rafters were originally undersized for <strong>the</strong>irspan and had deflected, causing slates <strong>to</strong> lift or slip,and thus allowing water <strong>to</strong> enter <strong>the</strong> ro<strong>of</strong> space. Tocorrect <strong>the</strong> problem, this additional supportstructure was added during ro<strong>of</strong> repair worksIdentifying defectsThe sagging or deflection <strong>of</strong> a ro<strong>of</strong> should not alwaysbe diagnosed as a ro<strong>of</strong> failure; some unevenness orundulation in an old ro<strong>of</strong> can add <strong>to</strong> a building’saes<strong>the</strong>tic and his<strong>to</strong>ric character, provided it is not asymp<strong>to</strong>m <strong>of</strong> ongoing structural instability and is notallowing water <strong>to</strong> enter <strong>the</strong> building. However,deflection which has caused <strong>the</strong> leading edges <strong>of</strong> <strong>the</strong>slate <strong>to</strong> tilt up or protrude is a problem once waterpenetration <strong>to</strong> <strong>the</strong> interior ro<strong>of</strong> space occurs. Inextreme cases, ro<strong>of</strong> rafters can deflect <strong>to</strong> <strong>the</strong> extent <strong>of</strong>stressing <strong>the</strong> nail fixings and breaking <strong>the</strong> nail headthrough <strong>the</strong> slate. Defects <strong>of</strong> this type should be dealtwith without delay.48