12.07.2015 Views

portuguese national inventory report on greenhouse gases, 1990

portuguese national inventory report on greenhouse gases, 1990

portuguese national inventory report on greenhouse gases, 1990

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Industrial ProcessesEmi SF6 (t) = Stock SF6 (t) * (EF/100)where:Emi SF6 (t) - Equipment use emissi<strong>on</strong>s, including leakage emissi<strong>on</strong>s, servicing andmaintenance;Stock SF6 (t) - total SF 6 gas in existence at year t in all electrical equipments;EF – Emissi<strong>on</strong> Factor, corresp<strong>on</strong>ding to the percentage of SF 6 in stock at year t that isemitted to atmosphere.4.3.5.16.2.3 EDP Produção, Tejoenergia and TurbogásThe used methodology was identical to the <strong>on</strong>e described in “EDP Distribuição”.Disposal or retiring units were not included in the <str<strong>on</strong>g>inventory</str<strong>on</strong>g> as emissi<strong>on</strong> sources because,according to industry experts, the collecti<strong>on</strong> of gas at end of lifetime is d<strong>on</strong>e in a systematic andefficient way. Manufacturing and installati<strong>on</strong> emissi<strong>on</strong>s were assumed to be included inemissi<strong>on</strong>s from equipment usage.4.3.5.16.3 Emissi<strong>on</strong> FactorsThere are different emissi<strong>on</strong> factors for:- REN;4.3.5.16.3.1 REN- EDP Distribuição;- EDP Produção;- Tejoenergia;- Turbogás.The database <strong>on</strong> SF 6 repositi<strong>on</strong>s by equipment was available for the period 2003-2010. For theperiod 1995-2002, an average of the estimated loss (0.38 percent) for the period 2003-2010was c<strong>on</strong>sidered.4.3.5.16.3.2 EDP DistribuiçãoIn EDP Distribuição different emissi<strong>on</strong> factors were c<strong>on</strong>sidered for:- Gas Circuit Breakers:all circuit breakers are “Closed Pressure” equipments and the emissi<strong>on</strong> factor is 2.6percent/year as proposed <strong>on</strong> table 8.3 of “2006 IPCC Guidelines for Nati<strong>on</strong>alGreenhouse Gas Inventories” for “Closed Pressure Electrical Equipment”;- Outdoor Gas Insulated Switchgears;all outdoor gas insulated switchgears are “Sealed Pressure” equipments and theemissi<strong>on</strong> factor is 0.2 percent/year as proposed <strong>on</strong> table 8.2 of “2006 IPCC Guidelinesfor Nati<strong>on</strong>al Greenhouse Gas Inventories” for “Sealed Pressure Electrical Equipment”;Portuguese Nati<strong>on</strong>al Inventory Report 2013MAMAOT4-73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!