12.07.2015 Views

Series VM - SMC Pneumatics (Ireland)

Series VM - SMC Pneumatics (Ireland)

Series VM - SMC Pneumatics (Ireland)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Series</strong> <strong>VM</strong>PrecautionsBe sure to read before handling. Refer to p.0-33 to 0-36 for Safety lnstructions and common precautions.WarningMountingConditions for mechanical operationDo not move the mechanical operation beyond the operating limitposition, as this could damage the mechanical valve itself andlead to equipment malfunction.Actuator StrokeOperate the mechanism within the stroke range that has beenobtained through the formula given below. (Do not move beyond theoperating limit position.)Operating stroke: P.T. + 0.5 X O.T.<strong>Series</strong><strong>VM</strong>1000<strong>VM</strong>100<strong>VM</strong>200<strong>VM</strong>400VZM500VZM400VFM300VFM200ActuatorT.T.=4.8mmBasic(T.T.=2.5mm)Roller leverOne way roller leverBasicRoller leverOne way roller leverStraight plungerRoller plungerCross roller plungerBasicRoller leverOne way roller leverStraight plungerRoller plungerCross roller plungerBasicRoller leverOne way roller leverStraight plungerRoller plungerCross roller plungerBasicRoller leverOne way roller leverStraight plungerRoller plungerActuator Stroke(mm)3.7 to 4.7(2.2 to 2.4)3.5 to 4.43.5 to 4.42.2 to 2.94.3 to 5.34.3 to 5.32.7 to 3.42.7 to 3.42.7 to 3.44.0 to 4.98.7 to 10.79.5 to 11.74.5 to 5.44.5 to 5.44.5 to 5.42.5 to 3.46.2 to 8.26.5 to 8.74.5 to 5.44.5 to 5.44.5 to 5.42.0 to 2.94.2 to 6.04.7 to 6.72.5 to 3.42.5 to 3.4For straight and roller plunger styles, there is a groove indicating P.T.and T.T. for stroke adjustment.Definition of SymbolsF.P. (Free Position) ................ No external force applied.O.P. (Operating Position) ........ Internal valve opening position.T.T.P. (Total Travel Position) ...... Includes over travel.O.F. (Operating Force) .......... Operating force required to initialvalve opening position.F.O.F. (Full Operating Force) ....Required force to total travel position.P.T. (Pre-Travel)......................From free position to initial valve operatingposition.O.T. (Over Travel)....................From initial valve operating position tototal travel position.T.T (Total Travel) ....................From free position to total travel position.Air Flow CalculationRefer to the p.0-36 for air flow calculations.Q = 22.2S PL(PH – PL)273θ + 273Cautions·············(1 formula)This product cannot be used for applications in which the pressuremust be sealed because there will be a slight leakage. Consult <strong>SMC</strong>for this type of application.SAVASAVA<strong>VM</strong>/VRVH3.5-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!