ANALYSIS OF BEAM AND COLUMNThe depth D varies depending onPRECAST BEAMthe span.A depth of 280 mm was used forappartements with 5.0 m span inAddis Ababa.The longitudnal section of a typicalprecast beam is shown in fig-4.FIG-4 typical longitudnal section of precast beamPRECAST BEAMk x= x/dfrom this we can get the value ofx.This value is checked against thecentroidal axis of the beam and itdetermines whether the beam actsas a T-beam or a rectangular section.mine the value of k z.A S=M/K Z*d*f ydThe above equation is used to determinethe area of steel.check for shearThe shear force that comes to thestructure equalsv sd= p d*l/2This value is compared with thecode requirements of the sectionand then the appropriate shearforce equation is used to determinethe reinforcement to be provided.The longitudnal section of a typicalprecast beam is shown in fig-4.The same graph is used to deter-ANALYSIS OF BEAM AND COLUMNThe beam is the primary structurethat supports the precast beams .There are two types of beams usedin this approachit to wall under and columns.Given a masonry stiffening wallthat is constructed into the frameit can be expected that due to therestraints of the frame to the stiffeningBut due to imperfect constructionof the wall & also quality of hollowblocks it will be difficult to assumethat the wall will totally carry& transfer the load from pre-castbeam & the wall above. And therefore- Beam in U shaped HCB (supportedby the wall)-These were wall the wall will act as a di-agonal within the frame and significantlyin designing the girder beams, the wall is assumed to carry someused in class B HCB wallsreduces the loads imposed percentage of the vertical load.- Beam with out wall support on it. The function of the stiffenerwall is only limited by the shear Additional horizontal reinforcementBeam in U shaped HCBAs it is mentioned above it carriesload that comes from the precastbeam and wall above and transfercapability . Tension forces will bemainly eliminated by the framevertical members if the mortar jointb/n the horizontal frame member &the wall provides sufficient contact.within the hollow block maybe considered to upgrade the wallshear load bearing capacity.STRUCTURAL DESIGN OF COST EFFICIENT APPARTEMENTS CALCULATIONS71Addis AbabaCity Government

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!