12.07.2015 Views

System pro M compact® - Piti Group

System pro M compact® - Piti Group

System pro M compact® - Piti Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>System</strong><strong>pro</strong> M compact ® Selection tablesAccessories S 200, SN 201,Busbars and accessories for MCBs S 200, F 200, DS 200SN 201, RCDs F 200 and DS 200 series and other seriesConn. Module Phases Order Bbn Price Price Weight Packcapacity details 4016779 1 piece group 1 piece unitmm 2 Type code Order code EAN kg pc.End capsEND 1.1PS-END 0PS-END bbn-No. 4012233Main circuit breaker busbarEND 1.1 2CDL 200 011 R0011 638913 0.001 50PS-END 0 2CDL 200 001 R0004 652261 0.001 50PS-END 2CDL 200 001 R0001 514729 0.001 50PS-END 1 2CDL 200 001 R0002 570114 0.001 50PS-END SP 2CDL 200 110 R0001 646505 0.001 50PS-END 1 SP 2CDL 200 110 R0002 646512 0.001 50PS-END 3 2CDL 200 001 R3001 654302 0.001 50PS-END 3.1 2CDL 200 001 R3002 654319 0.001 50PSB-END 3 GHV0 361 325 R0001 556304 0.001 50PSB-END 4 GHV0 361 325 R0002 556403 0.001 503-phase busbar (10 mm 2 ) for connecting main circuit breaker E 463/3-KB and <strong>pro</strong> M compactdevices incl. end caps. No. of poles: 12 (1 x E 463/3-KB + 9 x S 201)12 3 PS 3/12 E463 2CDL230004R1012 51741 6 0.220 304Loads depending on supply point and required connection capacityEnd feedingcomb and oblong-hole busbars (type KS)busbar blocks(type PS/PSB )cross section/mm 2 10 12 20 24 36 10 16 30max. supply currentI S/phaseA 63 65 90 100 130* 63 80 120** If fed via the terminals, always ensure that the following values are not exceeded, irrespective of the current carrying capacity(I S) of the busbar:For S 200 and S 200M series: max. 110 A.For S 280 series: max. 140 A.Non-end feeding (center or elsewhere on the rail)comb and oblong-hole busbars (KS-type)busbar blocks(type PS/PSB)cross section/mm 2 10 12 20 24 36 10 16 30max. current in branchI E/phasemax. supply currentI E/phaseA 100 110 150* 170* 220* 100 120* 160*Adepends on cross section* If fed via the terminals, always ensure that the following values are not exceeded, irrespective of the current carrying capacity(I S) of the busbar:For S 200 and S 200M series: max. 110 A.For S 280 series: max. 140 A.Overall dimensions ...................... pag. 12/15ABB4/21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!