12.07.2015 Views

System pro M compact® - Piti Group

System pro M compact® - Piti Group

System pro M compact® - Piti Group

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>System</strong><strong>pro</strong> M compact ®Selection tablesCommand devicesE 234 electronic timersE 234RemarksLegendControl supply voltage not applied / Output contact openControl supply voltage applied / Output contact closedA1-Y1/B1 Control input with voltage-related triggeringTerminal designations on the device and in the diagramsThe 1st c/o contact is always designated 15-16/18.The 2nd c/o contact is designated 25-26/28.The n/o contacts of the star-delta timers are designated with 17-18 and 17-28.Control supply voltage is always applied to terminals A1-A2.Function of the yellow LEDThe yellow LED R glows as soon as the output relay energizes and turnsoff when the output relay de-energizes.ON-delay(Delay on make)CT-ERD, CT-MFDThis function requires continuous control supply voltage for timing.Timing begins when control supply voltage is applied. The green LEDflashes during timing. When the selected time delay is complete, theout put relay energizes and the flashing green LED turns steady. If controlsupply voltage is interrupted, the output relay de-energizes and the timedelay is reset. Control input A1-Y1/B1 of the CT-MFD is disabled whenthis function is selected.OFF-delay with auxiliary voltage(Delay on break)CT-AHD, CT-MFDThis function requires continuous control supply voltage for timing. Ifcontrol input A1-Y1/B1 is closed, the output relay energizes immediately.If control input A1-Y1/B1 is opened, the time delay starts. The green LEDflashes during timing. When the selected time delay is complete, theoutput relay de-energizes and the flashing green LED turns steady. Ifcontrol input A1-Y1/B1 recloses before the time delay is complete, thetime delay is reset and the output relay does not change state. Timingstarts again when control input A1-Y1/B1 re-opens. If control supplyvoltage is interrupted, the output relay de-energizes and the time delayis reset.A1-A215-18, 25-2815-16, 25-26green LEDt = adjusted time delayt< t2CDC 252 106 F0206A1-A2A1-Y1/B115-18, 25-2815-16, 25-26green LEDt< t2CDC 252 107 F02066t = adjusted time delayImpulse-ON(Interval)CT-VWD, CT-MFDThis function requires continuous control supply voltage for timing. Theoutput relay energizes immediately when control supply voltage isapplied and de-energizes after the set pulse time is complete. The greenLED flashes during timing. When the selected pulse time is complete,the flashing green LED turns steady. If control supply voltage is interrupted,the output relay de-energizes and the time delay is reset. Controlinput A1-Y1/B1 of the CT-MFD is disabled when this function is selected.Impulse-OFF with auxiliary voltage(Trailing edge interval)CT-MFDThis function requires continuous control supply voltage for timing.If control supply voltage is applied, opening control input A1-Y1/B1energizes the output relay immediately and starts timing. The green LEDflashes during timing. When the selected pulse time is complete, theoutput relay de-energizes and the flashing green LED turns steady.Closing control input A1-Y1/B1, before the time delay is complete, deenergizesthe output relay and resets the time delay. If control supplyvoltage is interrupted, the output relay de-energizes and the time delayis reset.A1-A215-18, 25-2815-16, 25-26green LEDt = adjusted pulse timet< t2CDC 252 108 F0206A1-A2A1-Y1/B115-18, 25-2815-16, 25-26green LEDt< t2CDC 252 109 F0206t = adjusted pulse timeFlasher, starting with the ON time(Recycling equal times, ON first)CT-EBD, CT-MFDApplying control supply voltage starts timing with symmetrical ON & OFFtimes. The cycle starts with an ON time first. The ON & OFF times aredisplayed by the flashing green LED, which flashes twice as fast duringthe OFF time. If control supply voltage is interrupted, the output relayde-energizes and the time delay is reset. Control input A1-Y1/B1 of theCT-MFD is disabled when this function is selected.Flasher, starting with the OFF time(Recycling equal times, OFF first)CT-MFDApplying control supply voltage starts timing with symmetrical ON & OFFtimes. The cycle starts with an OFF time first. The ON & OFF times aredisplayed by the flashing green LED, which flashes twice as fast duringthe OFF time. If control supply voltage is interrupted, the output relayde-energizes and the time delay is reset. Control input A1-Y1/B1 of theCT-MFD is disabled when this function is selected.A1-A215-18, 25-2815-16, 25-26green LEDtt = adjusted flashing timet2CDC 252 029 F0206A1-A215-18, 25-2815-16, 25-26green LEDtt = adjusted flashing timet2CDC 252 030 F0206ABB 6/47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!