12.07.2015 Views

System pro M compact® - Piti Group

System pro M compact® - Piti Group

System pro M compact® - Piti Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>System</strong><strong>pro</strong> M compact ®Selection tablesSTDCommand devicesUniversal dimmer for phase control and reverse phase controlUniversal dimmer for phase control and reverse phase controlUniversal dimmer STD-500 U and the connected power extension unit STD-420 E are suitable forthe brightness control of:- glow lamps- 230 V halogen glow lamps- lv halogen glow lamps with conventional transformer (phase control)- electronic transformers for lv halogen glow lamps (reverse phase control) e.g.: ABB ETR-70-230,105-230, 150-230The STD-500 U dimmer can be operated by one or more unlit pushbuttons (N- or L-controlled) orvia a data line:- EIB control element SB/S- Powernet control element PSBPower unit STD-420 E is used to boost the connected load and is controlled exclusively by the presetcommand of the STD-500 U dimmer. The parallel connection of the outputs of the universal highperformancedimmer and the pertaining power extensions (up to 6 units; connection with enclosedRJ 12 line cut to length) allow for a dimming power of 3,000 W/VA max at one load line.Not suitable for dimming fluorescent lamps, transformers with current monitor and high-reactancetransformers.Description/applicationPowerlossOrderdetailsBbn4011395Price1 piecePricegroupWeight1 piecePack.unitW Type codeOrder codeEANkg pc.high-performancedimmer6 STD-500 U GJB0 006 590 A0178 06692 8 1extension 6 STD-420 E GJB0 006 590 A0179 06693 5 1rotary operationelement– STD-OCD GJB0 006 590 A0183 06698 0 1button operationelement– STD-OCP GJB0 006 590 A0181 06695 9 1timer operationelement– STD-OCT GJB0 006 590 A0185 07056 7 16Note: Load and control cables must not be laid in one cable.Technical featuresRated voltage230 V ~ ± 10%, 50/60 HzRated current STD U 2.17 ASTD E 1.83 AMax. connected load U 500 W/VAE 420 W/VAPower extension1 U + max. 6 E/phase = > max. 3 kVAMin. connected load STD U 60 W/VASTD E 200 W/VAMax. line length100 m pushbutton cable, 2 m data lineInterference suppressionCEAmbient temperature0 to + 45°C, higher temperatures reduce the powerElectronic <strong>pro</strong>tection against short circuit, overload, excessive temperature, automatic load recognition, soft-OFF function optional, memory function, minimum brightness control, visual overload indicationConnected load / ambient temperature diagram2CDC 052 081 F0207Overall dimensions ...................... pag. 12/33ABB 6/39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!