<strong>System</strong><strong>pro</strong> M compact ®Technical detailsParticular supply sources and loadsMCBsIn lighting systems <strong>pro</strong>tection against overloads is not necessary if the number of light points is clearlydefined (no overloads).Moreover, the Standard in force for these systems recommends the omission of <strong>pro</strong>tection againstoverloads in circuits in which unwanted tripping may <strong>pro</strong>ve hazardous, e.g.: circuits which supplyfire-fighting equipment.Single-phase transformer (primary voltage 230 V)-1P and 1P+N MCBsPn [kVA] In [A] ucc (%) Circuit-breaker on primary side (1) and (2)0.1 0.4 13 S 2* D1 o K10.16 0.7 10.5 S 2* D2 o K20.25 1.1 9.5 S 2* D3 o K30.4 1.7 7.5 S 2* D4 o K40.63 2.7 7 S 2* D6 o K61 4.2 5.2 S 2* D10 o K101.6 6.8 4 S 2* D16 o K162 8.4 2.9 S 2* D16 o K162.5 10.5 3 S 2* D20 o K204 16.9 2.1 S 2* D40 o K405 21.1 4.5 S 2* D50 o K506.3 27 4.5 S 2* D63 o K638 34 5 S 290 D8010 42 5.5 S 290 D10012.5 53 5.5 S 290 D100Single-phase transformer (primary voltage 400 V)-2P MCBsPn [kVA] In [A] ucc (%) Circuit-breaker on primary side (1) and (2)1 2.44 8 S 2* D6 o K61.6 3.9 8 S 2* D10 o K102.5 6.1 3 S 2* D16 o K164 9.8 2.1 S 2* D20 o K205 12.2 4.5 S 2* D32 o K326.3 15.4 4.5 S 2* D40 o K408 19.5 5 S 2* D50 o K5010 24 5 S 2* D63 o K6312.5 30 5 S 2* D63 o K6316 39 5 S 290 D8020 49 5 S 290 D100Three-phase transformer (primary voltage 400 V)-3P, 3P+N and 4P MCBsPn [kVA] In [A] ucc (%) Circuit-breaker on primary side (1) and (2)5 7 4.5 S 2* D20 o K206.3 8.8 4.5 S 2* D20 o K208 11.6 4.5 S 2* D32 o K3210 14 5.5 S 2* D32 o K3212.5 17.6 5.5 S 2* D40 o K4016 23 5.5 S 2* D63 o K6320 28 5.5 S 2* D63 o K6325 35 5.5 S 290 D8031.5 44 5 S 290 D8040 56 5 S 290 D8050 70 4.5 S 290 D10010S 2*.. = S 200, S 200 M, S 200 P(1) With modular or magnetic only circuit-breakers, without thermal adjustment, thermal <strong>pro</strong>tection is required for the transformer’ssecondary winding.(2) Breaking capacity selected according to estimated Icc at the point where the breaker is installed.Selection tables ............................... pag. 2/2ABB10/75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!