12.07.2015 Views

DRAFT 7/12/05 - MHz Electronics, Inc

DRAFT 7/12/05 - MHz Electronics, Inc

DRAFT 7/12/05 - MHz Electronics, Inc

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SH-110 Dry Scroll Vacuum Pump<strong>DRAFT</strong> 7/<strong>12</strong>/<strong>05</strong>InstallationSafetyDo not remove or modify any safety or insulating equipmentfrom the pump. To do so may create a serious safetyhazard and may void the warranty.WARNINGCAUTION❑ This pump is capable of pumping airand inert gases only. It is not designedto pump explosive, flammable, corrosiveor particulate forming gases. Theycan cause bodily injury, explosion, orfire.❑ Install in an area that is not exposedto rain, steam, or excessive humidity.They can cause electric shock, shortcircuits, and severe bodily injury.❑ Before reconfiguring the pumpvoltage, or inspecting or servicing thepump, be sure the electrical supply isdisconnected.❑ The gas ballast must be sealed wheneverpumping any gas not intended tobe vented to the atmosphere.Although the pump can pump traceparticulates normally found in theatmosphere, it is not designed toprocess solids, chemicals, powders,solvents, condensates, or other particulates.They can damage the equipment,degrade its performance, or shorten itsuseful life.CAUTIONElectrical ConnectionsThe pump can be configured for low voltage, 100 VAC to115 VAC, or for high voltage, 200 VAC to 230 VAC.The pump as delivered from the factory is configured forlow voltage. To change the pump voltage follow this procedure:WARNINGDo not block the fan ducts. Blockingthese ducts can cause pump overheating.A pump surface temperature inexcess of 65 °C (150 °F) is potentiallydamaging. If such conditions areobserved, turn the pump off and allow itto cool. Disassemble, inspect for damage,and repair, if necessary.Risk of electric shock. Disconnect thepump from electrical power mainsbefore attempting to change the voltageconfiguration.1. Verify your electrical supply voltage.2. Use a small flat blade screwdriver to release the fuseholder from the power entry module.3. Carefully pop out the white plastic assembly andreinsert with the desired operating voltage showingoutward.4. Reinsert the fuse holder into the power entry module.Startup1. Check that the inlet screen is installed before beginningoperation.WARNINGDo not insert a finger or any foreignobject in the path of the fan; seriouspersonal injury may result or the pumpmay be damaged.2. Operate the pump at an ambient temperature of 5 °Cto 40 °C (41 °F to 104 °F), otherwise damage to thepump or shortened operating life may result.18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!