12.07.2015 Views

Manual - Hawk Measurement Systems!

Manual - Hawk Measurement Systems!

Manual - Hawk Measurement Systems!

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sensor Value0.0%Acoustic Switch Series<strong>Manual</strong>Rev 1.5, Feb 2013Acoustic Switch Series<strong>Manual</strong>Rev 1.5, Feb 2013FLOW CHARTSOFTWARE TREEOn first start up there isno security code protection.Percentage abovewhich the Relaywill be in State 2*.Percentage Sensor below Valuewhich the 0.0% Relaywill be in State 1*.Press} PressPressCALTo CalibrateMax/Min capturedSensor UnLock Value % sinceLast history 0 log reset,or last Cal MountingCALoperationNormal Running DisplayPress to view unitoperation diagnosticsDIAGNOSTICSto view informaiton about cur-While the unit is in RUN mode you can pressrent unit settings & operating characteristics.Current detected signal in %Sensor Value 0% full signal100% all signal blockedBlockedChuteSensor 1E1DistanceSigna1Selected ApplicationCurrently selected sensor for diagnosticsPress at the same time to switchbetween sensor 1 & 2 (in this menu only)Distance between sensors.May be displayed as double or triplevalue depending on chute conditions.Signal strength in voltage.2.5V maxDiagnostic0%Current sensor valueis always displayedon 2nd linePressTo QuickSetflow chartCALCurrent switchQuickSetdelay timeQuickSet Menucovers all parametersrequired for standardsetups.AdvancedPressAdvanced Menucovers less commonlyused or advancedparameters.CALTo Advancedflow chartRecov1Noise1Gain1Current recover gain% of sensor. Unit applies recovergain to maintain maximum possible signal strength.External noise interference % detected by sensor.Value may fluctuate during inactive process & emptychutes due to transducer ringing.Total Gain% useage of sensor.Calibrated starting gain + recover gain.PressRUNto return to normal operationSignalAverage signal strengthbeween both sensors.2.5V maxMinMinimum recorded sensorvalue % in logNormalUnit StatusNormal / CommRetryMaxMaximum recorded sensorvalue % in logSignal 1.86V0.0%Received Signal strengthTempDelayAmbient temperatureat sensorCurrent switch delaycount down. Value will beslightly lower due toresponse timeSW OffSW OnSensor value requiredfor switch off conditionSensor value requiredfor switch on conditionGain 10.2%0.0%Gain result of mounting12calibration13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!