12.07.2015 Views

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MODELSPGV-100G – 1" plastic globe valvePGV-101G – 1" plastic globe valve withflow controlPGV-100A – 1" plastic angle valvePGV-101A – 1" plastic angle valve withflow controlPGV-100MB – 1" plastic globe valve,no flow control, male thread x barbPGV-101MB – 1" plastic globe valve,with flow control, male thread x barbPGV-100MM – 1" plastic globe valve,no flow control, male x male threadPGV-101MM – 1" plastic globe valve,with flow control, male x male threadPGV-151 – 1½" plastic angle/globe valvewith flow controlPGV-201 – 2" plastic angle/globe valvewith flow controlPGV Pressure Loss in PSIGPM 1" Globe 1" Angle 1½" Globe 1½" Angle 2" Globe 2" Angle1 1.1 1.05 1.9 1.010 1.9 1.015 1.6 1.020 3.3 2.0 3.0 3.0 1.0 1.030 6.1 3.0 3.0 3.0 1.0 2.040 3.0 3.0 2.0 2.050 4.0 3.5 1.0 1.<strong>060</strong> 5.0 4.0 2.0 2.080 5.5 4.5 3.0 2.0100 5.0 3.0120 6.0 5.0PGV Pressure Loss in Barsm 3 /hr 1" Globe 1" Angle 1½" Globe 1½" Angle 2" Globe 2" Angle0.23 0.08 0.071.14 0.13 0.072.27 0.13 0.073.41 0.11 0.074.54 0.23 0.14 0.21 0.21 0.07 0.076.81 0.42 0.21 0.21 0.21 0.07 0.149.08 0.21 0.21 0.14 0.1411.36 0.28 0.24 0.07 0.0713.63 0.34 0.28 0.14 0.1418.17 0.38 0.31 0.21 0.1422.71 0.34 0.2127.25 0.41 0.34All models of PGV valvesfeature internal manualbleed, ensuring a neat, dryvalve box.VALVESDIMENSIONS• 1" Globe and Male x Male:5" H x 4½" L x 2½" W(13 cm H x 11 cm L x 6 cm W)• 1" Male x Barb:5" H x 5½" L x 2½" W(13 cm H x 14 cm L x 6 cm W)• 1" Angle:5½" H x 3½" L x 2¾" W(14 cm H x 9 cm L x 7 cm W)• 1½" Globe/Angle:7½" H x 5¾" L x 4½" W(19 cm H x 15 cm L x 11 cm W)• 2" Globe/Angle:8" H x 6¾" L x 5¼" W(20 cm H x 17 cm L x 13 cm W)OPERATING SPECIFICATIONS• Flow: .2 to 120 GPM (0.04 to 27.2m 3 /hr; 0.7 to 454.2 l/min)• Pressure: 20 to 150 PSI(1.4 to 10.3 bars; 138 to 1034 kPa)• Heavy-duty solenoid: 24VAC, 370mAinrush current, 190mA holding current,60 cycles; 475mA inrush current,230mA holding current, 50 cyclesPGV Pressure Loss in kPal/min 1" Globe 1" Angle 1½" Globe 1½" Angle 2" Globe 2" Angle3.8 7.58 6.8918.9 13.10 6.8937.9 13.10 6.8956.8 11.03 6.8975.7 22.75 13.79 20.70 20.70 6.90 6.90113.5 42.06 20.68 20.70 20.70 6.90 13.80151.4 20.70 20.70 13.80 13.80189.3 27.60 24.10 6.90 6.90227.1 34.50 27.60 13.80 13.80302.8 37.90 31.00 20.70 13.80378.5 34.50 20.70454.2 41.40 34.50Charts based on full-open fl ow control position.OPTIONS AVAILABLE• Accu-Set pressure regulator• Reclaimed water identification handlePGV-101 models (part number269205) for PGV-151/201 models(part number 412705)• DC latching solenoid(part number 458200)• Solenoid conduit cover(part number 464322)SPECIFICATION GUIDEMODELPGVFEATURES100G = 1" Globe Valve, no Flow Control101G = 1" Globe Valve, with Flow Control100A = 1" Angle Valve, no Flow Control101A = 1" Angle Valve, with Flow Control100MB = 1" Globe Valve, no Flow Control,Male Thread x Barb100MM = 1" Globe Valve, no Flow Control,Male x Male101MM = 1" Globe Valve, with Flow Control,Male x Male151 = 1½" Globe/Angle Valve, with Flow Control201 = 2" Globe/Angle Valve, with Flow ControlEXAMPLE: PGV - 100G - S - ASOPTIONS FACTORY INSTALLEDS = Slip x Slip (1" Models Only)B = BSP ThreadsDC = DC Latching SolenoidOPTIONS USER INSTALLEDAS = Accu-Set Pressure Regulator(1½" and 2" Models Only)R = Reclaimed Water Identifi cationHandle or TagCC = Conduit Cover55

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!