IMMS The affordable water management tool to monitor and control a network ofirrigation systems from a single central location.MODELSIMMS-CD – Central Control SoftwareIMMS-SI-MOD – Site Interface Unit, Standard Phone ModemIMMS-CI-HW – Controller Interface Unit, HardwireIMMS-R – Radio KitIMMS-SI-HW – Site Interface Unit, HardwireIMMS-CCC – Central Computer Communication Unit, HardwireDIMENSIONSCOMPONENT HEIGHT WIDTH DEPTH SHIPPING WT.IMMS-SI (HW or MOD) 16"/406 mm 11.5"/292 mm 4.25"/108 mm 18.7 lbs/8.48 kgsIMMS-CI-HW 8.9"/226 mm 9.9"/251 mm 4.3"/109 mm 5.66 lbs/2.57 kgsIMMS-CCC 1.5"/38 mm 4.25"/108 mm 6"/152 mm 1.96 lbs/.89 kgs(excluding external plug-in transformer)CONTROL CAPABI<strong>LIT</strong>IES• Manage irrigation systems at up to 100 different sites from a single centralized computer.• Each site managed can have up to 100 controllers networked into the site interface. The IMMS system can network with <strong>Hunter</strong> ICC, Pro-C, and SRC controllers.• Manage all controller programming data from the central computer.• Manual functions: activate, deactivate manual or automatic waterings from the central computer.• Initiate rain-off or rain-delay features by controller or globally.• Manage “no water days” up to 365 days in advance globally, by site, or by controller. This allows an irrigation manager to set specific days for maintenance, events, etc.• Easily program cycle and soak waterings for maximum water efficiency (ICC only).• Manages watering windows and no-water days with global and site-specific settings.MONITORING CAPABI<strong>LIT</strong>IESConfigure rain, wind and freeze sensors for real-time responses to weather conditions, and monitor their status remotely. Sensor data can be implemented locally withindividual controllers or shared across an entire site.React to system flow conditions through optional Flow-Clik IMMS flow sensors. This will shut controllers down automatically during over-flow conditions (line breaks,broken sprinklers), saving water and reducing liability concerns.COMMUNICATIONS CAPABI<strong>LIT</strong>IESIMMS can operate as an on-site hardwired ccan also operate as a wide-area network via telecommunications may be any combination of hardwire and radio interfaces.CENTRAL COMPUTER SOFTWARE AND REQUIREMENTS• Windows ® 2000 or Windows ® XP operating system with minimum Intel ® Pentium ® III processor, 366 MHz or higher. At least 128 Mb of RAM, 30 Mb of hard diskspace, and CD-ROM drive requireSerial Port if CCC is to be used. Mouse or other pointing device.• Easy-to-use software with icon based navigation provides fast program set-up and ongoing management.• Locations, controllers and stations can be user-assigned actual names and site descriptions for easy reference.• Built-in calendar program allows for scheduling of maintenance events (mowing, fertilizing, etc.).• Extensive reporting section generates tab -tain trends.INTERFACE SPECIFICATIONSRugged, key-lockable cabinets can be instalinternal 24 VAC (UL, CE) transformer.WIRING SPECIFICATIONSDEVICES WIRE TYPE DISTANCEPC to Central Computer Communication unit (CCC*) Standard serial cable (DB9) 6 ft./2 mCCC* to Site Interface (SI) <strong>Hunter</strong> Model GCBL (18/4, two twisted pair, shielded) 10,000 ft./3 kmSI to additional Controller Interface (CI) <strong>Hunter</strong> Model GCBL (18/4, two twisted pair, shielded) 10,000 ft./3 kmand then to each subsequent CIInterface (SI or CI) to local controller 18/5 wire (Paige P7183 or equivalent) 6 ft./2 mPC to Modem-equipped Site Interface (IMMS-SI-MOD) Public Telephone network No limitAll telephone modem connections Standard RJ11 telephone wire 6 ft./2 m*Not required for modem systems.86
Communication Options:IMMS offers more communications options than ever before, to stretch your control, and your savings even further!1. HARDWIRE: Simple low-cost central control for self-contained sites, when central PC ison same site as the controllers.• Easy, affordable color-coded wiring (<strong>Hunter</strong> GCBL). Use IMMS-CCC next to the computer to insert signals onto long-haul cable.• Robust signal resistant to electrical noise and surge.• Proven technology with no fees and no license.rH A R D W I R E C O M P O N E N T SMODELIMMS-CCCIMMS-SI-HWIMMS-CI-HWGCBL100GCBL300GCBL500DESCRIPTIONCentral Computer Communications unit (forhardwire units)Site Interface for Hardwire SystemsController Interface for Hardwire Systems100' (30 m) Cable for IMMS Hardwire300' (90 m) Cable for IMMS Hardwire500' (150 m) Cable for IMMS HardwireCENTRAL CONTROLS2. MODEM (Telephone): Affordable wide-area communications using dial up modems for 1 to 100 Site Interfaces (dedicated analogline only).• Uses technology you already own (computer’s internal modem,connected to public telephone system).• Lowest cost alternative for many, with no distance limitation(local telephone charges may apply).• Automatic dialing of all sites at programmable intervals.3. CELLULAR/GSM: Modems for long-range, wireless communications to remote sites.• Wireless communications can eliminate costly telephone line drops toremote locations (local cellular charges may apply).• Control your irrigation where land-based telephone servicesare unavailable.M O D E M C O M P O N E N T SMODELIMMS-SI-MODNo CCC requiredDESCRIPTIONSite Interface for Modem SystemsN/AC E L L U L A R C O M P O N E N T SMODELCELLULAR INTERFACEIMMS-SI-HWDESCRIPTIONTBASite InterfaceNo CCC requiredN/A4. UHF RADIO (450-470 MHZ): Narrowband radios broadcast IMMS control signals around individual sites, for the ultimate in installationconvenience and long-term reliability.UHF radio is an option to any version of either SI or CI for local area communications only. The SI can have radio and/or hardwirefor local area, and hardwire, modem or cellular for wide-area connection to the computer.• Available for either Site Interface (SI) or Controller Interface (CI).IMMS-R does not increase external dimensions of the interface.• 1⁄2 to 2 mile range (depending on local terrain and antenna placement).IMMS-R is only designed for communications on-site and is notdesigned to connect the central computer to a Site Interface…combineon-site radio with modem or cellular SI for maximum flexibility.• FCC/Industry Canada license required. International customers maypurchase mounting kit (IMMS-R-KIT) and source radio module locally.S P E C I F I C A T I O N G U I D EEXAMPLE: IMMS - SI - HW - ER A D I O C O M P O N E N T SMODELIMMS-RIMMS-R-KITIMMS-ANT2IMMS-ANT3FCC/Industry Canada LicenseDESCRIPTIONOptional Radio kit for Site/Controller Interfaces (add to any SI or CI)International radio-ready kit, includes mounting brackets for SI and CIOptional lid mounted antenna for ICC-SAT plastic pedestal controllerOptional remote high-performance antenna for coverage enhancementRequired - contact distributor for assistanceOperating Frequency Range: 450-470 MHz, frequency synthesized, programmableBandwidth: 12.5 kHzOutput Power: 2 WattsType Acceptance: FCC and Industry Canada (others available internationally)MODELIMMSCOMPONENTSI = Site InterfaceCOMMUNICATIONSHW = HardwireMOD = ModemPOWER OPTIONSE = Euro/International, 230VACCI = Controller InterfaceHW = HardwireCCC* = Central Computer Communication UnitA = Australian 240VACE = Euro/International, 230VACCD = SoftwareR** = Radio KitGCBL100 = 100' (30 m) Cable for IMMS HardwireGCBL300 = 300' (90 m) Cable for IMMS HardwireGCBL500 = 500' (150 m) Cable for IMMS Hardwire* CCC only requires separate Power Option for Australian use (SI and CI do not).** IMMS-R includes radio module for North American use only (FCC/Industry Canada license required).For International orders specify IMMS-R-KIT and source compatible radio locally. Local regulations apply.The optional remote antenna(with stainless steel mountingbracket) can be added to furtherenhance UHF radio coverage.The optional IMMS-Rradio kit easily installswithin the CI (shown) or SI,eliminating the needfor hardwire.87
- Page 2 and 3:
ROTORSPGJ _________________________
- Page 4 and 5:
THE HIGHEST QUALITY PRODUCTSFrom ga
- Page 8 and 9:
PGJAll the features and benefits of
- Page 10 and 11:
PGP ®The world’s best selling re
- Page 12 and 13:
PGP ®The world’s best selling re
- Page 14 and 15:
I-10/I-20 UltraThe rotor with heavy
- Page 16 and 17:
I-10/I-20 UltraThe ultimate upgrade
- Page 18 and 19:
I-25/31 PlusEfficient, economical,
- Page 20 and 21:
I-25/31 PlusA winning combination o
- Page 22 and 23:
I-40/41 GroupThe top choice at spor
- Page 24 and 25:
I-40/41 GroupThe number one choice
- Page 26 and 27:
I-60A large turf rotor that meets t
- Page 28 and 29:
I-90Industry’s longest distance r
- Page 32 and 33:
PSFast, precise set-up. Adjusts eas
- Page 34 and 35:
32PSFast, precise set-up. Adjusts e
- Page 36 and 37:
SRSEconomy, convenience, and the ve
- Page 38 and 39: Pro-Spray ®A rugged contractor-fri
- Page 40 and 41: Institutional SprayRugged, water-sa
- Page 42 and 43: Adjustable Arc NozzlesQuick easy an
- Page 44 and 45: Fixed Pattern NozzlesSuperior match
- Page 46 and 47: Specialty NozzlesProviding innovati
- Page 48 and 49: Bubblers & Bubbler NozzlesA whole n
- Page 52 and 53: SRVSimple operation, reliable perfo
- Page 54 and 55: ASVAtmospheric backfl ow prevention
- Page 56 and 57: PGVA complete line-up of rugged, pr
- Page 58 and 59: PGV Jar-TopMaximum convenience, rel
- Page 60 and 61: HPVA heavy-duty residential valve m
- Page 62 and 63: ICVThe top-of-the-line valve you ca
- Page 64 and 65: ICV Filter Sentry A heavy-duty, hig
- Page 66: HBVConstructed of solid brass to ha
- Page 69 and 70: CONTROLLERSMODELSSRC-600i - 6-stati
- Page 71 and 72: MODELSEC-200i/201i - 2-station indo
- Page 73 and 74: MODELSPC-300i - base model indoor p
- Page 75 and 76: CONTROLLERSMODELSICC-800-PL - 8-sta
- Page 77 and 78: MODELSICC-800-M - 8-station control
- Page 79 and 80: IDS MODELSIDS-SP - Stainless Steel
- Page 81 and 82: SRRActivate sprinklers without walk
- Page 83: Wireless Valve SystemRugged, reliab
- Page 87: THE IRRIGATION MANAGEMENT AND MONIT
- Page 91: MODELSICC-800-SAT-SI-HW - 8-station
- Page 95 and 96: SENSORSMODELSMINI-CLIK - standard M
- Page 97 and 98: Wireless Rain-Clik The first reliab
- Page 99: Flow-ClikAutomatically shuts down s
- Page 103 and 104: HCVAn economical water-saver that e
- Page 105 and 106: 103
- Page 107 and 108: Precipitation RatesA brief overview
- Page 109 and 110: Slope EquivalentsPercent, Angle and
- Page 111 and 112: Residential and Light Commercial Ro
- Page 113 and 114: Installation GuideSRS, Pro-Spray ®
- Page 115 and 116: PGJ, PGP ® , I-20 Ultra, I-25 Plus
- Page 117 and 118: 115Friction Loss ChartsTECHNICAL IN
- Page 119 and 120: PVC Class 200 IPS Plastic Pipe(1120
- Page 121 and 122: 119TECHNICAL INFORMATIONPVC Schedul
- Page 123 and 124: 12112345678910111214161820222426283
- Page 125 and 126: 123TECHNICAL INFORMATIONType K Copp
- Page 127 and 128: Additional DataNominalPipeSize1 ⁄
- Page 129 and 130: Dial-up Modem ConnectionsAIControll
- Page 131 and 132: STATEMENT OF WARRANTYHunter Industr