12.07.2015 Views

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

HBVConstructed of solid brass to handle tough conditionsand resist contamination.An internal self-flushing filter and self-cleaningmetering rod help eliminate dirt particlesbefore they enter the solenoid chamber,effectively making this valve contamination-resistant.The HBV also features a stainless steelsolenoid seat, built-in flow control to assureaccurate flow management, and a surgicalqualitytoggle switch that provides easymanual operation through internal downstreambleed. So rugged and reliable, dirtywater will never be a problem again!Heavy-duty toggle switchMakes manual operation easyHBV Pressure Loss in PSIGPM 1" 1½" 2" 3"5 0.210 0.815 1.520 2.6 0.530 5.7 1.040 10.0 1.7 0.550 15.6 2.7 0.860 22.0 3.8 1.270 5.1 1.680 6.6 2.190 8.3 2.6100 10.1 3.2 2.4120 14.8 4.6 2.5140 19.0 6.3 2.5160 23.1 8.0 2.9200 13.9 4.0240 6.0280 8.2320 10.7360 13.2FEATURES & BENEFITSStainless steel seat in solenoid chamberPrevents rust and corrosionSlow closureStops water hammer, surge and noiseReinforced 600 lb. test diaphragm with integral O-ring sealLong life under extreme pressuresSPECIFICATION GUIDEMODELHBVFEATURES101E = 1" Globe Valve151E = 1½" Globe Valve201E = 2" Globe Valve301E = 3" Globe ValveHBV Pressure Loss in BarsEXAMPLE: HBV - 201E - Pm 3 /hr 1" 1½" 2" 3"1.14 0.002.27 0.103.41 0.104.54 0.20 0.006.81 0.40 0.109.09 0.70 0.10 0.0011.36 1.10 0.20 0.1013.63 1.50 0.30 0.1015.90 0.40 0.1018.17 0.50 0.1020.44 0.60 0.2022.72 0.70 0.20 0.2027.26 1.00 0.30 0.2031.80 1.30 0.40 0.2036.35 1.60 0.60 0.2045.43 1.00 0.3054.51 0.4063.59 0.6072.68 0.7081.76 1.90OPTIONSP = Pressure RegulationB = BSP ThreadsDC = DC Latching Solenoid (Field Installed)HBV Pressure Loss in kPal/min 1" 1½" 2" 3"18.9 1.1037.9 5.2056.8 10.3075.7 17.90 3.10113.6 39.30 6.90151.4 68.90 11.70 3.70189.3 110.00 18.30 5.70227.1 151.90 26.20 8.30265.0 35.20 11.00302.8 45.50 14.10340.7 57.20 17.90378.5 69.60 22.10 16.00454.2 102.20 31.70 17.00530.0 131.20 43.40 17.0<strong>060</strong>5.7 159.40 55.20 20.00757.1 95.80 28.00908.4 41.001059.8 57.001211.2 74.001362.6 91.00Charts based on full-open non-regulated settingposition. Minimum fl ow on 1" valve is 9.5 l/min.MODELSHBV-101E – 1" brass globe valveHBV-151E – 1½" brass globe valveHBV-201E – 2" brass globe valveHBV-301E – 3" brass globe valveDIMENSIONS• HBV-101E4½" H x 4 3 /8" L x 5½" W(11 cm H x 11 cm L x 14 cm W)• HBV-151E8" H x 6" L x 8" W(20 cm H x 15 cm L x 20 cm W)• HBV-201E9" H x 7" L x 9" W(23 cm H x 18 cm L x 23 cm W)• HBV-301E10" H x 11 5 /8" L x 10" W(25 cm H x 29 cm L x 25 cm W)• HBV-101EP4½" H x 4 3 /8" L x 5½" W(11 cm H x 11 cm L x 14 cm W)• HBV-151EP8" H x 6" L x 7½" W(20 cm H x 15 cm L x 19 cm W)• HBV-201EP9" H x 7" L x 7¾" W(23 cm H x 18 cm L x 20 cm W)• HBV-301EP10" H x 11 5 /8" L x 11" W(25 cm H x 29 cm L x 28 cm W)• Female inlet/outlet: NPT or BSPOPERATING SPECIFICATIONS• Flow: 5 to 360 GPM(1.14 to 81.8 m 3 /hr; 18.9 to1362 I/min)• Pressure: 20 to 200 PSI (1.4 to 14.0bars; 138 to 1379 kPa) Note: Inletpressure must exceed outlet pressureby a minimum of 15 PSI (1.0 bars;103 kPa) on pressure regulated models• Electrical: 24VAC, 50/60 cycle solenoidpower requirement – 335mA(.335A; 8VA) inrush current; 200mA(.200A; 4.9VA) holding currentOPTIONS AVAILABLE• Pressure regulation• BSP threads• DC latching solenoid, field installed(part number S16305)64

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!