12.07.2015 Views

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VALVESMODELSICV-101G – 1" plastic globe valveICV-151G – 1½" plastic globe valveICV-201G – 2" plastic globe valveICV-301G – 3" plastic globe/angle valveAccu-Set Pressure RegulatorDIMENSIONS• ICV-101G5½" H x 4¾" L x 4" W(14 cm H x 12 cm L x 10.2 cm W)• ICV-151G7¹/8" H x 6 7 /8" L x 5½" W(18 cm h x 17.5 cm L x 14 cm W)• ICV-201G7¹/8" H x 6 7 /8" L x 5½" W(18 cm H x 17.5 cm L x 14 cm W)• ICV-301G10¾" H x 9¼" L x 7 3 /8" W(27.3 cm H x 23.5 cm L x 18.7 cm W)• Female inlet/outlet: 1", 1½", 2" & 3"NPT or BSPOPERATING SPECIFICATIONS• Flow: 0.10 to 300 GPM (0.06 to68.10 m 3 /hr; 0.9 to 1,135.5 l/min)• Pressure: 20 to 220 PSI (1.4 to 15.0bars; 138 to 1500 kPa)• Temperature: up to 150˚F (66˚C)• Heavy-duty solenoid: 24VAC, 370mAinrush current, 190mA holding current,60 cycles; 475mA inrush current,230mA holding current, 50 cycles• Accu-Set: 20 PSI (1.4 bars, 138 kPa)minimum operating pressure. Regulatesfrom 20 to 100 PSI (1.4 to 7.0bars; 138 to 689 kPa)OPTIONS AVAILABLEICV Pressure Loss in PSI3"GPM 1" 1½" 2" Globe Angle0.1 2.00.5 2.01.0 2.05.0 4.010.0 3.015.0 3.020.0 3.0 1.530.0 4.0 1.540.0 7.0 1.7 0.850.0 2.2 1.260.0 3.0 1.775.0 3.9 2.490.0 5.5 3.2100.0 7.0 4.2120.0 10.9 6.5135.0 12.7 7.9150.0 16.2 9.8 2.5 1.9175.0 13.3 3.0 2.4200.0 17.7 4.1 3.3225.0 5.3 4.3250.0 6.7 5.5275.0 8.3 6.9300.0 10.1 8.5Accu-Set : FINALLY, A PRESSURE REGULATORTHAT’S EASY TO SETWith the added option of Accu-Set on a <strong>Hunter</strong> ICVvalve, you can reliably adjust and regulate pressuresanywhere from 20 to 100 PSI, and be certain the settingyou select will never waver. Accu-Set can be fieldinstalled to any ICV valve in seconds, without tools.Plus, the best part is the ease of setting the unit – justturn to the pressure you want on the easy-reading dial.No other pressure regulating device is as simple to use(just one more reason to choose <strong>Hunter</strong>).ICV Pressure Loss in Bars3"m 3 /hr 1" 1½" 2" Globe Angle0.06 0.140.11 0.140.23 0.141.14 0.282.27 0.213.41 0.214.54 0.21 0.106.81 0.28 0.109.08 0.48 0.12 0.0511.36 0.15 0.0813.63 0.21 0.1217.03 0.27 0.1620.44 0.38 0.2222.71 0.48 0.2927.25 0.75 0.4530.66 0.87 0.5434.10 1.12 0.67 .17 .1339.70 0.92 .20 .1645.42 1.22 .28 .2351.10 .36 .3056.80 .46 .3862.50 .57 .4868.10 .70 .59ICV Pressure Loss in kPa3"l/min 1" 1½" 2" Globe Angle0.9 13.71.9 13.73.8 13.718.9 27.537.9 20.656.8 20.675.7 20.6 10.3113.5 27.5 10.3151.4 48.2 11.7 5.5189.2 15.1 8.2227.1 20.6 11.7283.8 26.8 16.5340.6 37.9 22.0378.5 48.2 28.9454.2 75.1 44.8510.9 87.5 54.4567.8 111.6 67.5 17.2 13.1662.4 91.7 20.7 16.5757.0 122.0 28.3 22.8851.6 36.5 29.6946.3 46.2 37.91040.9 57.2 47.61135.5 69.6 58.6• Accu-Set pressure regulator• Reclaimed water ID handle(part number 385905 - 1", 1½" & 2")(part number 515005 - 3")• DC latching solenoid(part number 458200)• Solenoid conduit cover(part number 464322)SPECIFICATION GUIDEMODELICVFEATURES101G = 1" Globe Valve151G = 1½" Globe Valve201G = 2" Globe Valve301G = 3" Globe ValveEXAMPLE: ICV - 201G - DC - ASOPTIONS FACTORY INSTALLEDB = BSP ThreadsDC = DC Latching SolenoidOPTIONS USER INSTALLEDAS = Accu-Set Pressure RegulatorR = Reclaimed Water Identifi cation HandleCC = Conduit Cover61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!