12.07.2015 Views

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CONTROLLERSMODELSSRC-600i – 6-station, Indoor Model with120 VAC Plug-in TransformerSRC-900i – 9-station, Indoor Model with120 VAC Plug-in TransformerSRC-601i – 6-station, Indoor Modelwithout Plug-in TransformerSRC-901i – 9-station, Indoor Modelwithout Plug-in TransformerDIMENSIONS• SRC8¼" H x 8½" W x 2¼" D(21 cm H x 22 cm W x 6 cm D)SPECIFICATIONS & FEATURES• Station run time: 0-99 minutesin 1-minute increments• Start times: 4 per day, per program,for up to 12 daily starts• Day schedule: 7-day calendar or trueodd-even programming with 365-daycalendar clock• AM/PM or 24 hour clock option• Start time stacking• One button manual start and advance• Transformer input: 120VAC, 60 Hz(transformer not included withexport units)• Transformer output: 24VAC, 0.75A• Station output: 24VAC, 0.3Aper station• Maximum total output: 24VAC, 0.6A,includes master valve circuit• Battery: Not required for programbackup. 9 volt alkaline battery may beused to program controller in absenceof AC power.• Non-volatile memory for programdata (no battery required to maintainprogram)• Master valve output: 24VAC, 0.3A• Overload fuse: 0.75A, sparefuse provided• Surge protection: primary MOV-type• Rain sensor override compatible withmost major brands• Preset test cycle on program “C”• UL listed• Central control compatible with<strong>Hunter</strong> IMMS systemAS EASY TO INSTALL AS IT IS TO USEThe SRC controller is easy to use. Eveneasier to install, with an exceptionally largewiring compartment and a handy provisionfor conduit, as well as a wall mountingbracket. There’s no measuring, no pilotholes, no special templates necessary. Justposition the bracket, install two screws(provided) and hang the controller. Onceagain, easy does it.SPECIFICATION GUIDEMODELSRCEXAMPLE: SRC - 600iFEATURES600i = 6-Station Controller, Indoor Model with 120 VAC Plug-in Transformer900i = 9-Station Controller, Indoor Model with 120 VAC Plug-in Transformer601i = 6-Station Controller, Indoor Model without Plug-in Transformer901i = 9-Station Controller, Indoor Model without Plug-in Transformer67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!