12.07.2015 Views

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

LIT-060 Hunter 2004-2005 Product Catalog - Ewing Irrigation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

VALVESMODELSICV-101G-FS – 1" plastic globe valvewith Filter SentryICV-151G-FS – 1½" plastic globe valvewith Filter SentryICV-201G-FS – 2" plastic globe valvewith Filter SentryICV-301G-FS – 3" plastic globe/anglevalve with Filter SentryAccu-Set pressure regulatorDIMENSIONS• ICV-101G5½" H x 4¾" L x 4" W(14 cm H x 12 cm L x 10.2 cm W)• ICV-151G7¹/8" H x 6 7 /8" L x 5½" W(18 cm h x 17.5 cm L x 14 cm W)• ICV-201G7¹/8" H x 6 7 /8" L x 5½" W(18 cm H x 17.5 cm L x 14 cm W)• ICV-301G10¾" H x 9¼" L x 7 3 /8" W(27.3 cm H x 23.5 cm L x 18.7 cm W)• Female inlet/outlet: 1", 1½", 2" & 3"NPT or BSPOPERATING SPECIFICATIONS• Flow: 0.10 to 300 GPM (0.06 to68.10 m 3 /hr; 0.9 to 1,135.5 l/min)• Pressure: 20 to 220 PSI (1.4 to 15.0bars; 138 to 1500 kPa)• Temperature: up to 150˚F (66˚C)• Heavy-duty solenoid: 24VAC, 370mAinrush current, 190mA holding current,60 cycles; 475mA inrush current,230mA holding current, 50 cycles• Accu-Set: 20 PSI (1.4 bars, 138 kPa)minimum operating pressure. Regulatesfrom 20 to 100 PSI (1.4 to 7.0bars; 138 to 689 kPa)OPTIONS AVAILABLE• Accu-Set pressure regulator• Reclaimed water ID handle(part number 385905 - 1", 1½" & 2")(part number 515005 - 3")• DC latching solenoid(part number 458200)• Solenoid conduit cover(part number 464322)ICV Pressure Loss in PSI3"GPM 1" 1½" 2" Globe Angle0.1 2.00.5 2.01.0 2.05.0 4.010.0 3.015.0 3.020.0 3.0 1.530.0 4.0 1.540.0 7.0 1.7 0.850.0 2.2 1.260.0 3.0 1.775.0 3.9 2.490.0 5.5 3.2100.0 7.0 4.2120.0 10.9 6.5135.0 12.7 7.9150.0 16.2 9.8 2.5 1.9175.0 13.3 3.0 2.4200.0 17.7 4.1 3.3225.0 5.3 4.3250.0 6.7 5.5275.0 8.3 6.9300.0 10.1 8.5SPECIFICATION GUIDEMODELICVFEATURES101G = 1" Globe Valve151G = 1½" Globe Valve201G = 2" Globe Valve301G = 3" Globe ValveA SUPERIOR SELF-CLEANING SYSTEMThe ICV standard filter can become clogged by largeamounts of small debris commonly found in reclaimedwater, wells, or in lakes and ponds. But with FilterSentry , the filter is scoured clean by a wiper that slidesup and strokes the full length of the filter when thevalve opens. The wiper continues to providescrubbing action on the upper part of thefilter during valve operation. For yourconvenience, Filter Sentry can be addedeasily after the valve is installed.ICV Pressure Loss in Bars3"m 3 /hr 1" 1½" 2" Globe Angle0.06 0.140.11 0.140.23 0.141.14 0.282.27 0.213.41 0.214.54 0.21 0.106.81 0.28 0.109.08 0.48 0.12 0.0511.36 0.15 0.0813.63 0.21 0.1217.03 0.27 0.1620.44 0.38 0.2222.71 0.48 0.2927.25 0.75 0.4530.66 0.87 0.5434.10 1.12 0.67 .17 .1339.70 0.92 .20 .1645.42 1.22 .28 .2351.10 .36 .3056.80 .46 .3862.50 .57 .4868.10 .70 .59EXAMPLE: ICV - 201G - FS - ASOPTIONS FACTORY INSTALLEDFS = Filter SentryB = BSP ThreadsDC = DC Latching SolenoidICV Pressure Loss in kPa3"l/min 1" 1½" 2" Globe Angle0.9 13.71.9 13.73.8 13.718.9 27.537.9 20.656.8 20.675.7 20.6 10.3113.5 27.5 10.3151.4 48.2 11.7 5.5189.2 15.1 8.2227.1 20.6 11.7283.8 26.8 16.5340.6 37.9 22.0378.5 48.2 28.9454.2 75.1 44.8510.9 87.5 54.4567.8 111.6 67.5 17.2 13.1662.4 91.7 20.7 16.5757.0 122.0 28.3 22.8851.6 36.5 29.6946.3 46.2 37.91040.9 57.2 47.61135.5 69.6 58.6OPTIONS USER INSTALLEDAS = Accu-Set Pressure RegulatorR = Reclaimed Water Identifi cation HandleCC = Conduit Cover63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!