IDT TestingEquipmentTesting for this project was performed using a Tinius-Olsen (T-O) Super L loadframe calibrated up to 120,000 lbf. The system is non-dynamic, closed-loop servohydraulic<strong>and</strong> is computer controlled using the s<strong>of</strong>tware program MTestWindows byAdmet. In addition to the T-O’s st<strong>and</strong>ard load measurement device (pressuretransducer), a new electronic 25,000 lbf, fatigue-rated Tovey load cell (Model FR20-25K) was mounted in-line between the loading table <strong>of</strong> the T-O <strong>and</strong> the pistonconnected to the lower IDT loading platen/strip, as specified in T 322-07. The Toveyload cell was cross-calibrated up to 19,000 lbf using the T-O which had beencalibrated by a certified T-O technician approximately 10 months earlier. Just daysbefore IDT testing began, the same T-O technician again calibrated the T-O <strong>and</strong>noted that no adjustments to the previous calibration were necessary thus verifyingthe cross-calibration <strong>of</strong> the Tovey load cell. The T-O load data output is used by theMTestWindows program for control purposes. However, for purposes <strong>of</strong> calculatingcreep compliance <strong>and</strong> tensile strength, the Tovey load data was used because <strong>of</strong>the load cell’s faster response <strong>and</strong> higher resolution relative to the pressuretransducer used in the T-O. Because all data was acquired at a rate <strong>of</strong> 10 Hz, afaster load cell response was necessary to determine with greater accuracy the timeat which maximum loads occurred.Specimen deformations were measured using new, MTS strain-gauge typeextensometers (Model OSDME). The extensometers were factory calibrated for twodifferent full-scale displacement ranges: vertical, 2.000 <strong>and</strong> 0.2000 mm compressiononly (utilized during strength <strong>and</strong> creep testing, respectively); horizontal, ±0.500 <strong>and</strong>±0.0500 mm compression <strong>and</strong> tension (utilized during strength <strong>and</strong> creep testing,respectively). During creep compliance testing, the smaller range was used forincreased resolution.Data acquisition was accomplished using LabView 8.0 by National Instruments.Inputs to data acquisition were the T-O load output <strong>and</strong> table position, the Toveyload cell, <strong>and</strong> the four MTS extensometers.The temperature chamber is MTS model 651.34. The temperature is controllablefrom -30 to +100°C, ±0.2°C. Figure 1 shows the equipment configuration.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!