12.07.2015 Views

EDS3365 Manual in PDF format - Bender

EDS3365 Manual in PDF format - Bender

EDS3365 Manual in PDF format - Bender

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Product descriptionParts listThe <strong>EDS3365</strong> <strong>in</strong>sulation fault location system comprises the follow<strong>in</strong>g components:1 pc. Alum<strong>in</strong>ium case with carry<strong>in</strong>g strap1 pc. PGH183 test device1 pc. EDS165-3 <strong>in</strong>sulation fault evaluator, accumulators <strong>in</strong>cluded1 pc. PSA3320 current clamp (diameter 20mm)1 pc. PSA3352 current clamp (diameter 52mm)1 pc. Power supply cable3 pcs. Safety measur<strong>in</strong>g lead, black1 pc. Safety measur<strong>in</strong>g lead, green/yellow4 pcs. Safety claw grip (3 x black, 1 x green/yellow) with 2A fuses1 pc. BNC Adaptor / banana plug -> transformer2 pcs. Banana plug1 pc. Accumulator charg<strong>in</strong>g set (not with the <strong>EDS3365</strong>-13 version)1 pc. TGH1320E operat<strong>in</strong>g manualBefore commission<strong>in</strong>g, please check that all the components listed above are<strong>in</strong>cluded. Do not undertake any work with an <strong>in</strong>complete system. If anycomponents are miss<strong>in</strong>g, please contact a technical adviser at BENDER.Supply voltageThere are two different <strong>EDS3365</strong> <strong>in</strong>sulation fault location systems available:• <strong>EDS3365</strong>• <strong>EDS3365</strong>-13The difference between them is the supply voltage for the PGH183:• PGH183 - supply voltage: AC 230 V• PGH183-13 - supply voltage: AC 90 …132 VAttentionOptionsPrior to commission<strong>in</strong>g, it is absolutely essential to check whether the supply voltageof the <strong>EDS3365</strong> system matches the voltage of the ma<strong>in</strong>s supply. Operation of the<strong>EDS3365</strong> with the wrong supply voltage can result <strong>in</strong> the destruction of the PGH183test device.When work<strong>in</strong>g with the <strong>EDS3365</strong>, only use those components which are suppliedwith the system. In particular, do not use other current clamps, measur<strong>in</strong>g leads ormeasur<strong>in</strong>g term<strong>in</strong>als.The <strong>EDS3365</strong> represents a complete system. In addition to the PSA3320 and PSA3352current clamps which are supplied with the system, measur<strong>in</strong>g current transformerscan be connected to the EDS165-3 <strong>in</strong>sulation fault evaluator. These may be BENDERmeasur<strong>in</strong>g current transformers which are already <strong>in</strong>stalled <strong>in</strong> the system.The follow<strong>in</strong>g types of transformers are suitable:Measur<strong>in</strong>g current transformer W1-35/8000 or W08/8000Split-core type measur<strong>in</strong>g transformer WS50x80/8000Important: normal commercial measur<strong>in</strong>g transformers must not be used!This also applies to additional current clamps or measur<strong>in</strong>g current transformersfrom the BENDER range.Attention: if transformers are not be<strong>in</strong>g used, they must not be left open <strong>in</strong> thesystem. In this case, the transformer term<strong>in</strong>als k u. 1 should be short-circuited.16TGH1320E/03.2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!