EDS3365 Manual in PDF format - Bender

EDS3365 Manual in PDF format - Bender

EDS3365 Manual in PDF format - Bender

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PRC470ALARM RS485RS485ONSLAVE ADDRESS + 110START2.5mAA3 A2 A1 A0 SLAVE RS485 STOP101 mAMASTERGENERATORONK1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12ALARM FAULTSLAVE ADDRESSA4 A3 A2 A1 A0onoffRS485TESTRESETMONITORPractical use• An alarm message signals an <strong>in</strong>sulation fault downstream of the sensor.• Measure along the lead with the EDS165-3 until you have found the faultlocation.• The fault location is found when the test current through the current clamp isat least 0.5 mA. On this po<strong>in</strong>t, see the chapter on SETTINGS ANDADAPTATIONS <strong>in</strong> the EDS473 operat<strong>in</strong>g manual.• For operat<strong>in</strong>g currents < 1 A, measurement is also possible by encircl<strong>in</strong>g oneconductor only. Attention: for currents > 10 A, this may produce the effectthat the current clamp can no longer be opened. This danger is particularlypresent <strong>in</strong> direct voltage systems. If this behaviour occurs, under nocircumstances use force, s<strong>in</strong>ce this would destroy the current clamp. Instead,you must switch off the relevant system. After this has been done, the currentclamp can be opened without the application of force.• For each measurement, wait for one cycle of the PGH473 test device(approximately 30 seconds).IT system (AC 20-265 V or DC 20-308 V)A1 A2 11 14 L1 L2 L3PGH473PGH473A B GND IN1 IN2 IN3EEDS startDisconnect the<strong>in</strong>sulation monitor<strong>in</strong>g devicedur<strong>in</strong>g the fault locationfrom the system!A1 A2 GND IN1 IN2 IN3 IN4 O1+ O1- O2+ O2-EDS-SystemA B 11 12 14 21 22 24EDS473-12A1 A2 K1 K2 K3 K4 K5 K6 K7 K8 K9I∆sA B R1 R2 l K12 K11 K10 11 12 14PRC470RS485 BusUse of an EDS165-3 <strong>in</strong> an IT system with a permanently <strong>in</strong>stalled EDS473 <strong>in</strong>sulationfault location system. In addition to the messages from PRC470 and EDS473-12, theportable EDS165-3 <strong>in</strong>sulation fault evaluator can be used to check <strong>in</strong>dividualsubcircuits and to display the test currents.38TGH1320E/03.2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!