Practical useSequence of the<strong>in</strong>sulation fault location• The central <strong>in</strong>sulation monitor<strong>in</strong>g device has signalled an <strong>in</strong>sulation faultthat is below the <strong>in</strong>sulation value the EDS system is able to locate. Pleaseobserve the characteristic curves with it <strong>in</strong> chapter ”Po<strong>in</strong>ts to be consideredbefore use”.• Read<strong>in</strong>g the relevant <strong>in</strong>sulation restistance on the LC display of the<strong>in</strong>sulation monitor<strong>in</strong>g device:Is the read value of the <strong>in</strong>sulation resistance smaller than the maximum<strong>in</strong>sulation fault of the EDS system that can be localized, change from theISOMETER to the EDS mode us<strong>in</strong>g S1.• Connect<strong>in</strong>g the PGH183 to the test current feed<strong>in</strong>g po<strong>in</strong>ts accord<strong>in</strong>g to theenclosed sketch.• Prepar<strong>in</strong>g the EDS163 evaluator:• Connect the two current clamps of similar construction (PSA3352, PSA3320)to the BNC extension leads and to the BNC adaptor.• Switch the operat<strong>in</strong>g mode selector switch to the EDS mode (I ∆n).• Carry out the follow<strong>in</strong>g software sett<strong>in</strong>gs:menu m1: set sensor to the current clamp <strong>in</strong> use (PSA3352,PSA3320)menu m3: memory offmenu m4: onmenu m5: frequency 50 Hz• Start of the EDS systemFirst encircle the PE conductor of the PGH183 with one of the twoconnected current clamps. When the measured test current I ∆son the LC-Display of the EDS165-3 exceeds 1 mA, then a successful location of the<strong>in</strong>sulation fault is possible.Afterwards disconnect the current clamp from the PE conductor.Now run the L+ and the L- through the current clamps, under nocircumstances through the PE conductor though.• Insulation fault location <strong>in</strong> the <strong>in</strong>stallation with the EDS system:Encircle the two redundant supply conductors lead<strong>in</strong>g to the consumers,each with one current clamp. When you do this, take <strong>in</strong>to considerationthat you really encircle the supply conductors belong<strong>in</strong>g to the sameconsumer. Pay attention to the identical direction of energy of both currentclamps (see sketch). Encircle all the parallel consumer subcircuits with thecurrent clamps. Consumer subcircuits with <strong>in</strong>sulation faults will be <strong>in</strong>dicatedby an alarm message on theEDS165-3.Attention: An alarm message occurs approximately 30 seconds afterconnect<strong>in</strong>g both the current clamps.42TGH1320E/03.2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!