12.07.2015 Views

Dimensional Metrology - Procontrol AMC

Dimensional Metrology - Procontrol AMC

Dimensional Metrology - Procontrol AMC

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

metemContact tips for narrow spacesIn applications with very narrow spaces, the extremely compact probes M916and M917 may be used. In spite of its compact size, the diameter of attachmentis Ø8h6. The cable outlet for M917 is axial, but in M916 it is radial.Please observe that the zero point is not adjustable in M916.Technical dataLinearityAccording to current practice, the linearityis stated as a percentage of thereading. Metem measuring probes areexceptionally linear, with constant sensitivityall along the measuring range.Measuring forceThe measuring force stated is valid whenthe probe is in a horizontal position.When used in a vertical position, about0.1 N should be added to this value,to take into account the weight of themoving anchor. In probes equipped witha gaiter, the springs included have beenadjusted to take into account the elasticityof the gaiter (± 20 %).Mechanically adjustable zeropointThe possibility of adjusting the probe’szero point above the measuring movementis a valuable feature of all Metemprobes (excl. M916 and M919).This may be utilized to place the tip in theoptimum measuring position, while therisk of influence from workpieces beingmoved is diminished.Compatible sensitivityThe complete range of Metem measuringprobes, from ± 1 mm measuring rangeand larger, produce the same outputvoltage when the scale reading is atmaximum. Because of that, every probemay be used with the amplifier adjustedto the same nominal sensitivity. (Doesnot apply to M910 or M919).CablesAll probes are supplied with 2 m ofscreened cable as a standard, and thecover material chosen provides goodresistance to cutting fluids.IP ratingAll Metem analogue probes (except thelow force probes) are certified for IP65.Compressed AirIn order to maximize the life span of theMetem analogue probes with pneumaticretract, the compressed air shall be bothclean and dry.IP ratingAll Metem probes are equipped with Viton gaiters to stop moisture and dust entering. Viton is chemically inert and does notdeteriorate when exposed to cutting fluids. All probes fulfil IP65 according to BS 5490:1977 category 2.CE markingAll our measuring probes are in complete compliance with relevant regulations, including EMC directives 89/336/EEG, butare not supplied with the CE marking (components are not to be marked). As the recommended carrier frequency is only 10kHz, it is unlikely that any connected interfaces or amplifiers will display any EMC problems.However, if connected to electronic digital circuits with fast transients, the probes may act as “antennas”. The probes and thecables are screened, but in such cases the shielding of the complete system installation should be reviewed.30Contact us at info@cej.se • Phone +46 (0) 16 15 06 40 • Fax +46 (0) 16 15 06 59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!