1.0 DESIGN1.3 SYSTEM DETAILSHeating SystemBoiler sited above the BoilerMateAny boiler used must be fitted with an overheatthermostat i.e. it must be suitable for use ina sealed system. The F & E cistern must be fitted at a heightwhich will provide the minimum head requiredfor the boiler and must be at least 250mmabove the highest point of the system.The height of the water level in the F & E cisternfrom the base of the store should be no greaterthan 10m.A gravity check valve should be fitted in theboiler return pipework to prevent gravitycirculation between the BoilerMate 2000 andthe boiler during dormant periods.An automatic air vent will be required on theflow adjacent to the boiler and dependingupon the pipe layout a manual air vent mayalso be required on the return adjacent tothe boiler. Boiler sited with dipped flow and returnpipes to the BoilerMateAny boiler must be fitted with an overheatthermostat i.e. it must be approved for use ina sealed system. An automatic air vent will be required on theflow and return connections adjacent to theboiler.The height of the water level in the F & E cisternmust provide the minimum head required bythe boiler and must be at least 250mm higherthan the highest point of the system. Page 14