APPENDIX BMANIFOLDSManifold type: 1 - Stock Code MIP 050(one bathroom, one en suite shower room, one cloakroom, one kitchen)Flow regulator(litres/minutes)Terminal fittingHot watermanifold outletsQuantityCold watermanifold outletsQuantity18 Bath tap 1 19 Hand basin 3 312 Kitchen sink 1 19 Toilet cistern None 39 Shower 1 112 Washing machine 1 19 Dishwasher None 1Total 7 11Two sets of manifolds are available as anoptional extra. Each set comprises a separatehot and cold water manifold. Both areprovided with a 22mm inlet connectionlocated centrally. All outlet connections are15mm compression. The centre to centredimension of each branch is 55mm.595mm595mm2 No 6mmfixing holesblank18 l/mm12 l/mm9 l/mminlet9 l/mm9 l/mm9 l/mm12 l/mmblank18 l/mm12 l/mm9 l/mm9 l/mminlet9 l/mm9 l/mm9 l/mm9 l/mm12 l/mm55mmA (hot)9 l/mm9 l/mm165mmB (cold)Manifold type: 2- Stock Code MIP 060(two bathrooms, one en suite shower room, one cloakroom, one kitchen,one utility room)Flow regulator(litres/minutes)Terminal fittingHot watermanifold outletsQuantityCold watermanifold outletsQuantity18 Bath tap 2 29 Hand basin 4 412 Kitchen sink 2 29 Toilet cistern None 49 Shower 1 112 Washing machine 1 19 Dishwasher None 1Total 10 15The arrangement of each manifold is suppliedas shown. This provides the best balance offlows but the flow regulators/duty of eachbranch can be changed if required as longas a reasonable balance is maintained. Ifit is necessary to change or clean the flowregulator this can be done without needingto drain the system by closing the valve andremoving the screwed cover below the whiteplastic cover.The manifolds are designed to be used withplastic pipework and are supplied completewith isolation valves and flow regulatorson each branch. They would normally beinstalled in the same cupboard as the thermalstorage appliance (as shown below) but canbe installed in another cupboard close to theappliance if required.595mm595mm85mm18 l/min12 l/minC12 l/min9 l/min(hot)inlet9 l/min9 l/min9 l/min9 l/min12 l/min18 l/min18 l/min9 l/mm12 l/min12 l/min9 l/min9 l/mm9 l/mmPage 37inlet9 l/min9 l/min9 l/min12 l/min18 l/min9 l/mm9 l/mm9 l/mm55mmD(cold)85mm90mm90mm195 mm<strong>BOILERMATE</strong> 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!