2.0 INSTALLATION2.2 INSTALLATIONThe BoilerMate 2000 incorporates a pumpoverrun for the boiler pump and terminal 6on the terminal strip (as shown on page 22)should only be used if the boiler requires apermanent live for another purpose.The boiler manufacturers wiring instructionsshould be read in conjunction with thismanual.Before switching on the electrical supply checkall the factory made terminal connections toensure they have not become loose duringtransit.Frost Protection1 2 3 4 5 6 7 8 9 10 11 12Frost Thermostat(make ontemperature drop)ApplianceControlBoard10Boiler PumpWhen frost protection is required for the wholehouse or where a base temperature is requiredduring cold weather, then a frost thermostatshould be wired across plug in terminals 21and 23 on the A.C.B board.An alternative to fitting a frost thermostwould be to set the programmer to constantduring the time required and adjust the roomthermostat to a suitable setting.When frost protection is required for theboiler circuit only a frost thermostat and pipemounted thermostat should be fitted. Thepipe thermostat should be mounted on theprimary return pipe adjacent to the boiler andboth thermostats should be wired from theterminal strip as shown opposite.Pipe MountedThermostat (break ontemperature rise)Page 24