12.07.2015 Views

GM 3000AC - WAGNER-Group

GM 3000AC - WAGNER-Group

GM 3000AC - WAGNER-Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EDITION 05/2007OPERATING MANUALPART NO. DOC364831<strong>GM</strong> <strong>3000AC</strong>6.1 FINISHING WORK AND CLEANINGDANGERExploding gas/ air mixture!Danger to life from flying parts and burns Never spray into a closed container. Earth the container.SIHI_0008_GBCleaning agent in the air duct!Functional faults caused by swollen sealsCAUTION Always point the spray gun down when cleaning. Ensure that neither paint nor cleaning agent enters the air duct.SIHI_0005_GB Note:Methylene chloride is not recommended as a flushing or cleaning solvent with this gun orany system components.1. Relieve the pressure from the gun and unit.2. Secure gun with trigger safety catch.3. Replace material with cleaning agent.4. Remove and clean the AirCoat nozzle. (see section 5.4.3)5. Pressurize the cleaning supply to approx. 4 MPa; 40 bar; 580 psi max. and thoroughlyflush the spray gun.6. Relieve spray gun and unit pressure!7. Secure gun with trigger safety catch.8. Clean gun body with a cleaning agent recommended by the manufacturer, and drywith a cloth.30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!