12.07.2015 Views

Time/Temperature Control Series 733/734 - Watlow

Time/Temperature Control Series 733/734 - Watlow

Time/Temperature Control Series 733/734 - Watlow

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

To mask an alarm …• When the SIL parameter is ON…• Press the <strong>Temperature</strong> key . This masks or "snoozes" the alarm messagefor 30 seconds, and energizes the alarm output relay.Error Codes• When the SIL parameter is OFF…• Press the <strong>Temperature</strong> key . This masks or "snoozes" the alarm messagefor 30 seconds, but does not energize the alarm relay.Error Code MessagesThe error code is visible in the display and alternates with the current display at a3 second rate. The list below outlines the standard error codes associated withthe <strong>Series</strong> <strong>733</strong>/<strong>734</strong>. They are designed to isolate specific problem areas and aidin troubleshooting your control. If the problem persists, consult the factory.ProblemEr01 -ROM (Read OnlyMemory) checksum errorEr02 -RAM (Random AccessMemory) checksum errorProbable CauseInternal ROM isdefective.Internal RAM is defective.Solution• Cycle power• Cycle powerçWARNING:Electrical noise or anoise event, excessenvironmentalmoisture or temperature,or vibrationmay cause<strong>Series</strong> <strong>733</strong>/<strong>734</strong>errors to occur. Ifthe cause of anerror is not otherwiseapparent,check for these.Er03 -Ambient sensor errorAmbient temperature isbelow 32°F/0°CFactory calibrationparameters have beenaltered.• Check ambient temperatureat the control.• Restore factorycalibration parameters.See Calibration section.Table 2 -Error CodeTroubleshootingEr04 -Configuration errorDefective microprocessor• Cycle powerEr05 -EEprom errorPower loss while storingdata.• Cycle powerEr06 -Zone 1 A/D (Analog toDigital Converter) UnderflowerrorEr07 -Zone 1 A/D overflow errorEr08 -Zone 2 A/D (Analog toDigital Converter) Underflowerror• Incorrect sensor type• Measuring temperatureoutside the sensorrange• Reversed sensor leadsOpen sensor• Incorrect sensor type• Measuring temperatureoutside the sensorrange• Check the InP1 parameter.Verify itmatches your sensor.• Check the InP1 parameter.Verify itmatches your sensor.• Check the InP2 parameter.Verify itmatches your sensor.˜NOTE:For Er06 throughEr09, always checkthe sensor andconnections for areversed or opensensor beforetrying the solutionlisted.Er09 -Zone 2 A/D overflow errorOpen sensor• Check the InP2 parameter.Verify itmatches your sensor.Alarms & Error Codes, Chapter 5 WATLOW <strong>Series</strong> <strong>733</strong>/<strong>734</strong> Program Manual 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!