1. DISPLAY AND OPERATION OF CRT/MDI B–<strong>62545EN</strong>/<strong>02</strong>[3–/6–digit B function]DGN0150#7BF1#6BF2#5 #4 #3 #2 #1 #0BF1BF2Strobe signal for the 3 low–order digits of the B codeStrobe signal for the 3 high–order digits of the B codeDGN0154#7#6#5#4#3B38#2B34#1B32#0B31DGN0155B28B24B22B21B18B14B12B11– For the 6–digit B function, code signals are output for every three digits.[High–speed interface] Auxiliary–functionoperation sequencesDGN 700.0=1 DGN 700.0=1Read auxiliary functionTo the next blockTo the next blockAuxiliary function code (BCD)Strobe (MF, SF,..)Behavior of functionCompletion (MFIN,...)DGN0150#7BF1#6BF2#5 #4 #3TF#2SF#1 #0MFDGN0115BFIN1 BFIN2 TFIN SFIN MFINMFIN, SFIN, TFIN Function completion signalsDGN0701#7 #6 #5CRST#4 #3 #2 #1 #0#5 CRST The emergency stop signal (*ESP), external reset signal (ERS), reset &rewind signal (RRW), or MDI reset button is on.DGN0<strong>02</strong>1#7 #6 #5 #4*ESP#3 #2 #1 #0DGN0121ERS*ESPDGN0104RRW*ESPERSRRW0 : The emergency stop signal is on.1 : The external reset signal is on.1 : The reset & rewind signal is on.– There is no DGNOS display for the MDI reset button.10