Autotrol Performa Valve - Pentair Residential Filtration

Autotrol Performa Valve - Pentair Residential Filtration

Autotrol Performa Valve - Pentair Residential Filtration

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TroubleshootingThe technology upon which the <strong>Autotrol</strong> <strong>Performa</strong>control valve is based is well established and proven inservice over many years. However, should a problem orquestion arise regarding the operation of the system,the control can very easily be serviced. For partsmentioned, refer to exploded views in the ReplacementParts section of this manual.IMPORTANT: Service procedures that require the waterpressure to be removed from the system are markedwith a ! after the possible cause. To remove waterpressure from the system, put the bypass valve orthree-valve bypass into the bypass position and openthe backwash drain valve (the seventh valve back fromthe control) with a screwdriver. Restore system waterpressure when the service work is completed.<strong>Valve</strong> TroubleshootingProblem Possible Cause Solution1. Control will not draw brine. A. Low water pressure.B. Restricted drain line.C. Injector plugged !D. Injector defective !E. <strong>Valve</strong> (2 and/or 4) not closed.2. Brine tank overflow. A. Brine valve (1) being held open.3. System using more or lesssalt than salt control is setfor.4. Intermittent or irregularbrine draw.5. No conditioned water afterregeneration.6. Control backwashes atexcessively low or highrate.7. Flowing or dripping water atdrain or brine line afterregeneration.8. Hard water leakage duringservice.B. Uncontrolled brine refill flow rate !C. <strong>Valve</strong> (3 or 4) not closed during brinedraw causing refill.D. Air leak in brine line.A. Inaccurate setting.B. Foreign matter in controller causingincorrect flow rates !C. Defective controller.A. Low water pressure.B. Defective injector !A. Unit did not regenerate.B. No salt in brine tank.C. Plugged injector !A. Incorrect backwash controller used.B. Foreign matter affecting controlleroperation !A. Drain valve (5 or 6) or brine valve (1)held open by foreign matter orparticle.B. <strong>Valve</strong> stem return spring on top plateweak.A. Improper regeneration.B. Leaking of bypass valve !C. O-ring around riser tubedamaged !A. Set pump to maintain 30 psi atconditioner.B. Remove restriction.C. Clean injector and screen.D. Replace injector.E. Remove foreign matter from disc andcheck disc for closing by pushing in onstem. Replace if needed.A. Manually operate valve stem to flushaway obstruction.B. Remove variable salt controller to clean.C. Flush out foreign matter by holding discopen and manually operating valve stem.D. Check all connections in brine line forleaks. Refer to instructions.A. Correct setting.B. Remove variable salt controller and flushout foreign matter. Manually positioncontrol to brine draw to clean controller(after so doing, position control to “purge”to remove brine from tank).C. Replace controller.A. Set pump to maintain 30 psi atconditioner.B. Replace both injector and injector cap.A. Check for power.B. Add salt.C. Clean injector. Flush with water.A. Replace with correct size controller.B. Remove controller and ball. Flush withwater.A. Manually operate valve stem to flushaway obstruction.B. Replace spring.A. Repeat regeneration making certain thatthe correct salt dosage is set.B. Replace O-ring.C. Replace O-ring.20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!