12.07.2015 Views

GX Works 2 Operating Manual Structured Project - Automation ...

GX Works 2 Operating Manual Structured Project - Automation ...

GX Works 2 Operating Manual Structured Project - Automation ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1.3 List of FunctionsOnline (common function)ReferenceMonitor -Monitor ModeMonitor (Write Mode)Start Monitoring (All Windows)Stop Monitoring (All Windows)Start MonitoringStop MonitoringChange Value Format (Decimal)Change Value Format (Hexadecimal)Device/Buffer Memory BatchSwitch the mode of the open window to "Monitor Mode"during monitoring.Switch the mode of the open window to "Monitor (WriteMode)" during monitoring.Start monitoring of all open windows.Stop monitoring of all open windows.Start monitoring of the open window.Stop monitoring of the open window.Display the current device value in decimal in programmonitoring.Display the current device value in hexadecimal in programmonitoring.Monitor device/buffer memory in batch.(Simple)(Common)Section 12.1Section 12.3.1Program ListMonitor the processing time of programs being executed. (Common)Interrupt Program ListMonitor the number executions of interrupt programs.Change Instance (Function Block) Select an instance of the function block to be monitored. Section 12.2SFC All Block Batch Monitoring Batch monitor all blocks in the SFC program.SFC Auto ScrollScroll the screen to display active steps automatically when (Simple)they are out of the screen during monitoring.Watch -Start WatchingStop WatchingRegister WatchLocal Device Batch Read + Save CSVStart monitoring the current values of registered devices/labels and intelligent function module.Stop monitoring the current values of registered devices/labels and intelligent function module.Register the selected devices to the Watch window.Read local device data from the programmable controllerCPU and saves them to a personal computer in CSV format.(Common)Debug (common function)ReferenceStart/Stop SimulationStart/stop simulation.Instructions Unsupported by SimulationDisplay a list of the instructions and devices used in theprogram unsupported by the simulation function.Modify ValueFor ladder and SFC (Zoom) programs, change the ON/OFF (Common)status and values of devices and labels used in the program.Forced Input Output Registration/CancellationRegister/cancel the forced input/output of the device 'X'/'Y'.Device Test with Execution Condition -Register Device Test with ExecutionConditionRegister the device test with execution condition.Check/Disable Register Device Testwith Execution ConditionBatch Disable Device Test withExecution ConditionCheck/disable the registration of device test with executioncondition.Cancel the device test with execution condition in batch.(Common)Sampling Trace -Open Sampling TraceDisplay the Sampling Trace screen.Scan Time MeasurementMeasure the scan time of a desired section.(Common)Step Execution -StopStop the step execution.CancelBreak ExecutionStep ExecutionExecution OptionCancel the step execution.Execute the break execution.Execute the step execution.Display the "Execution Option" screen of the step execution.(Common)2OVERVIEWSCREEN 3CONFIGURATIONPROGRAMMING 4PROCEDUREPROGRAM 5CONFIGURATIONS6SETTING LABELSCOMMON OPERATIONS7OF PROGRAM EDITORSEDITING ST 8PROGRAMS1EDITING STRUCTUREDLADDER PROGRAMS1.3.1 List of functions common to Simple project and <strong>Structured</strong> project 1 - 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!