Service Kit<br />

Number<br />

Description<br />

Adjustment<br />

Screw Kit<br />

991-112-003 Viton<br />

991-112-007 Buna-N<br />

Adjustment<br />

Screw Kit<br />

991-212-003 Viton<br />

991-212-007 Buna-N<br />

Maximum<br />

Setting<br />

Limiter<br />

(Zinc plated steel)<br />

991-022<br />

Lockwire Kit<br />

991-012<br />

<strong>Cartridge</strong> Control Kits<br />

Position Switch<br />

Protective Cover<br />

(6061-T6 Aluminium)<br />

991-043<br />

Use specifically with<br />

Control/<strong>Cartridge</strong><br />

CKCA-L** CKCD-L**<br />

CKCB-L** CPCA-L**<br />

CKCC-L**<br />

CKEA-L** CKED-L**<br />

CKEB-L** CPEA-L**<br />

CKEC-L**<br />

All models with an L<br />

adjustment control (Except<br />

Series 0 and counterbalance.)<br />

The maximum setting limiters<br />

can only be ordered as a kit at<br />

this time. Will be available as<br />

cartridge control options in<br />

the future with customer<br />

specified settings.<br />

Contact your Sun<br />

Distributor when ordering<br />

as cartridge control option.<br />

All M, Q and R controls<br />

(except solenoid operated<br />

cartridges).<br />

LOHC-Z**<br />

53,1 mm<br />

38,9 mm<br />

Manual<br />

Release<br />

Screw<br />

Locknut<br />

Description<br />

Back-up<br />

Ring<br />

Visit www.sunhydraulics.com for current list pricing and complete technical information on all Sun products.<br />

Seal<br />

Pin (2) Cap Existing <strong>Cartridge</strong><br />

Locking Wire<br />

53,1 mm<br />

38,9 mm<br />

Lead Seal<br />

(4) 1/4-20 SCHS x 101,6 mm LG<br />

95,3 mm<br />

Only cartridges date stamped “62”<br />

or earlier.<br />

Installation Instructions:<br />

Kit consists of 2 Driv-Lok pins<br />

(811-001-011), Hex Cap<br />

(375-020). To prevent any<br />

damage to nose end and/or any<br />

moving parts, only install this<br />

kit while cartridge is screwed<br />

into a cavity.<br />

1. Set adjustment to desired level<br />

within recommended range of<br />

valve and tighten jam nut to<br />

12Nm.<br />

2. Remove maximum setting<br />

stop ring from the adjust<br />

screw.<br />

3. Thread hex cap onto the adjust<br />

screw until it bottoms out<br />

against jam nut and tighten to<br />

12 Nm.<br />

4. Insert one of the Driv-Lok pins<br />

into the hex cap holes and tap<br />

into place using a hammer<br />

until flush. Repeat procedure<br />

with second Driv-Lok pin.<br />

5. Install is now completed.<br />

Installation:<br />

Threaded holes will need to be<br />

machined in the manifold to install<br />

cover.<br />

Number of Holes: 4<br />

Mounting Hole Thread:<br />

.250-20 UNC -2B<br />

Mounting Hole Depth: 13,5 mm<br />

182 Int’l <strong>Shortcut</strong> <strong>Catalogue</strong> #999-901-312